1-866-4 JJSTECH(1-866-455-7832)

Testo 310 Residential Analyzer Kit - 0563 3100

Item #:
0563-3100
Brand:
Testo
$725.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Testo 310 Residential Analyzer Kit - 0563 3100

Testo 310 Residential Analyzer Kit - 0563 3100

$725.00

0563 3100 310 Residential Analyzer Kit by Testo

The testo 310 has two measurement cells for O2 and CO, and a temperature sensor integrated into the flue gas probe. The gas sensors measure the exact oxygen and carbon monoxide content as well as the flue gas and ambient temperature. From these data, all relevant measurement parameters such as CO2 value, degree of effectivity and flue gas loss are calculated. The instrument stands out thanks to its easy handling and simple menu structurey. You can read off the measurement values confidently and conveniently from the well-lit display, even in bad light conditions. The fuels are stored not just as numbers, but are each described. At the top edge of the clear display, the symbols for the different measurement menus are always in view. The display and the dirt-insensitive keypad are clearly structured. Operation is very easy – even if you only have one hand free.

Kit Includes:

  • testo 310 analyzer
  • probe & hose
  • silicon tubing
  • extra particulate filters (5)
  • pressure plugs (5)
  • AC power supply/recharger (USB)
  • calibraton certificate
  • hard case

  • Robust and light instrument for daily use
  • 30 seconds sensor zeroing
  • O2 and CO measurement
  • Integrated magnets for easy fixing to burner

Applications:

  • Flue gas measurement
  • Draught measurement
  • Ambient CO measurement
  • Pressure measurement
Display Backlit 2-line display
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Weight Approx. 700 g
Dimensions 201 x 83 x 44 mm
Probe type Type K Meas. Range: -20 to +100.0 °C
Accuracy: ±1 °C
Resolution: 0.1 °C
Response time: < 50 s
Probe type CO Meas. Range: 0 to 4000 ppm
Accuracy: ±20 ppm (0 to 400 ppm); ±5% of mv (401 to 2000 ppm); ±10% of mv (2001 to 4000 ppm)
Resolution: 1 ppm
Response time: 60 s
Probe type Differential pressure Meas. Range: -40 to 40 hPa
Accuracy: ±0.5 hPa
Resolution: 0.1 hPa
Probe type Draught measurement Meas. Range: -20 to +20 hPa
Accuracy: ±0.03 hPa (-3.00 to +3.00 hPa); ±1.5% of mv (remaining range)
Probe type Exhaust gas loss measurement Meas. Range: 0 to 99.9%
Resolution: 0.1%
Probe type Electrochemical measurement O2 Meas. Range: 0 to 21 Vol. %
Accuracy: ±0.2 Vol. %
Resolution: 0.1 Vol. %
Probe type Efficiency Measurement (Eta) Meas. Range: 0 to 120 %
Resolution: 0.1%
Probe type Typ J (FeCuNi) Meas. Range: 0 to +400 °C
Accuracy: ±1 °C (0 to +100 °C); ±1.5% of mv (>100 °C)
Reaction time < 50 s