1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Touchpoint Plus Basic Wall Mount Controller, DC Powered, 8 x mA input with 12 x relay output with battery backup, MODBUS RTU - TPPLBDWA8SNBRNN

Item #:
TPPLBDWA8SNBRNN
Brand:
Honeywell Analytics
$5,887.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Touchpoint Plus Basic Wall Mount Controller, DC Powered, 8 x mA input with 12 x relay output with battery backup, MODBUS RTU - TPPLBDWA8SNBRNN

Honeywell Analytics Touchpoint Plus Basic Wall Mount Controller, DC Powered, 8 x mA input with 12 x relay output with battery...

$5,887.00

TPPLBDWA8SNBRNN Touchpoint Plus Basic Wall Mount Controller, DC Powered, 8 x mA input with 12 x relay output with battery backup, MODBUS RTU by Honeywell Analytics

Touchpoint Plus brings a whole new control experience to your small system of gas detectors. Touchpoint Plus is an easily configurable, wall mounted control system that supports up to sixteen channels of gas detection. Its modular approach enables you to take control and configure what you need for a wide range of applications.

The signature feature of the Touchpoint line is a user-friendly touchscreen interface, and the Touchpoint Plus takes it to a new level. With this unique interface, it's easier than ever to see the status of your system at a glance - maximizing the time you have to make the right decisions. The intuitive, multilingual interface, simplifies operation and reduces training requirements. The full colour traffic light style status indication provides clarity from a distance too.

Touchpoint Plus includes a comprehensive set of outputs as standard including common alarms and dedicated drives for remote audiovisual indicators. Its modularity enables you to customise your system to meet your specific application requirements. Selecting the right detector for use with your controller can deliver significant savings in startup costs and on-going operations. Our global partner network and dedicated application specialists are able to help make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system and operate it with confidence, ensuring the safety of your people and productivity of your site.

Delivering reliable control

  • Honeywell reliability from the most trusted experts in gas detection
  • Built-in battery backup for constant uptime
  • Robust, shockproof housing for a wide range of industrial environments

Flexible capabilities

  • Compatible with the full range of Honeywell gas detectors
  • Powered audiovisual alarms simplify field installation
  • Configuration includes easy grouping and voting alarm logic without specialist knowledge
  • Next-generation compatibility
  • Optional Modbus output for integration with a higher level system

Providing ease and efficiency

  • Quick and easy installation, configuration, commissioning and maintenance
  • Easy diagnostics, data and reporting
  • Minimised training time
  • Large colour touchscreen LCD
  • Multilingual capabilities
  • Green-yellow-red status at a glance
GENERAL SPECIFICATION
Capacity Up to 8 channels with base unit, up to 16 channels with expansion unit
Type of inputs 2 or 3 wires, mA, mV, max. 15W per channel, max 40W total (with dedicated A/V drive) / 68W total (without dedicated A/V drive)
Size (wall-mounted version) 426 mm x 300 mm x 156 mm (16.8" x 11.8" x 6.1")
Housing Material Polycarbonate ABS
Weight Max 8.5 kg (18.7 lb), max 17 kg (37.4 lb) with expansion unit
USER INTERFACE (UI) - CONTROLLER ONLY
Display 7" colour LCD touchscreen. Graphic User Interface
Visual indicators 3 LEDs for master indicators. LED for each channel. Green: Normal; Yellow: Fault: Inhibit; Red: Alarm
Audible alarm ≥ 70dB @ 1m
Button Common for reset/mute operation
Language English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese
POWER SUPPLY
Power AC 110/220VAC, 50-60Hz Manual switching
Power DC 18 to 32 VDC (+/-10%) Typical 24VDC
Power consumption Max 105W (including detector and external devices), max 210W with expansion unit
ENVIRONMENTAL
Operating -10°C to +55°C (14°F to +131°F) continuous, up to 95% RH (non-condensing), IP65 and NEMA 4X
Storage Instrument -25°C to +60°C. (-13°F to +140°F), up to 95% RH (non-condensing)
4~20mA input 2 or 3 wire, 2/4/8 channel modules, 10/12/16 with expansion unit
mV input Catalytic type flammable gas detectors (Honeywell models). 2/4/8 channel modules, 10/12/16 with expansion unit
Dual Input 2 channel mA + 2 channel mV module or 4 channel mA + 4 channel mV module
Relay output 12 or 24 relay outputs, NO/C/NC changeover, 1.7A@30VDC/250VAC, user configurable - energised/de-energised, latching/non latching, time delay
4~20mA output 4 or 8 isolated repeated mA outputs, 0-22mA, 0-100%FSD = 4-20mA
Common inputs Remote reset, remote inhibit
Common outputs Four powered A/V outputs for alarms and fault, three common alarm outputs
APPROVALS
Electromagnetic Compatibility and Electrical Safety EMC/RFI (EN 50270:2015)
LVD (EN 61010-1:2010)
CSA-C22.2 No. 61010-1-04
UL 61010-1 (3rd Edition) and 508
Performance EN 50271:2010; EN 60079-29-1:2016; EN 45544-1 /-2 /-3:2015;
EN 50104:2010 C22.2 No. 152-M1984, ISA 12.13.01
Safety Integrity IEC 61508:2010 Ed.2 SIL2, EN 50271:2010
Hazardous Location Class I, Division 2, Group A, B, C and D or non-hazardous only
Marine MED (Item No.: 3.54)
OTHERS
Backup battery 22.2V Lithium Ion Battery, 2600mAh capacity (>30 minutes for typical system)
Data logging Configuration, logged events and data
Communication MODBUS TCP, WEB monitoring and MODBUS RTU