- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Sensepoint Detector with Junction Box, 0-1,000ppm Hydrogen - SPSTAXG1
Item #:
SPSTAXG1
Brand:
Honeywell Analytics
Share this product:
SPSTAXG1 Sensepoint Detector with Junction Box, 0-1,000ppm Hydrogen by Honeywell Analytics
The Sensepoint range of flammable, toxic and Oxygen gas detectors offers users a cost-effective solution to their gas monitoring needs, in or out of doors and even in potentially explosive atmospheres. Supplied with a pre-wired junction box, this detector can be installed using conduit or armoured cable and glands depending on the specific needs of the application.
Sensepoint flammable and toxic gas detectors are designed for use in potentially explosive atmospheres, and allow for easy access to terminals via the hinged lid of the junction box. Installation should follow national guidelines using suitably approved armoured cable and glands or conduit.
Supplied with an earth continuity plate for increased resistance to the effects of RFI, the junction box offers the installer a choice of 1/2", 3/4" and M20 connection via conduit or armoured cable and Ex e certified cable glands. Terminals are suitable for use with screened 0.5mm2 (20AWG) to 2.5mm2 (14AWG) cross sectional area cable, as needed to ensure minimum operating voltage at the detector, depending upon installed cable length.
Sensepoint flammable, toxic and Oxygen gas detectors are designed for direct connection with the Honeywell Analytics' range of Touchpoint controllers.
One-Stop Shop
- Flammable, toxic and Oxygen versions available
- Suitable for indoor or outdoor use
- IP65 as standard
Proven Sensor Technology
- Surecell™ electrochemical sensors
- Poison resistant catalytic bead
- Fast and reliable
- Typical 2 to 5 years operational life
ATEX Certified
- Complies with the latest European standards
- Hazardous area and performance approvals
- Can be used for uncertified applications
Easy to Use
- Factory set operation
- Simple sensor replacement
- Minimal training required
Friendly Installation
- Universal junction box
- One box, three entries
- Metric and NPT compatibility
- Includes earth continuity plate for enhanced protection against RFI
Range of Accessories
- Weather Housing (IP66)
- Flow adaptor
- Collecting cone
General specification | ||||||
Use | Cost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards | |||||
Detectable gases | ||||||
Gas | Measuring range | Operating temperature | ||||
Ident | Name | 1 | 2 | 3 | Min | Max |
F | Flammable | 0-100% LEL | -40°C / -40°F | 50°C / 122°F | ||
O | Oxygen | 0-25% VOL | -15°C / 5°F | 40°C / 104°F | ||
C | Carbon Monoxide | 0-200ppm | 0-500ppm | -20°C / -4°F | 50°C / 122°F | |
H | Hydrogen Sulphide | 0-50ppm | 0-20ppm | 0-100ppm | -25°C / -13°F | 50°C / 122°F |
G | Hydrogen | 0-1000ppm | -5°C / 23°F | 40°C / 104°F | ||
L | Chlorine | 0-5ppm | 0-15ppm | -20°C / -4°F | 50°C / 122°F | |
S | Sulphur Dioxide | 0-15ppm | 0-50ppm | -15°C / 5°F | 40°C / 104°F | |
N | Nitrogen Dioxide | 0-10ppm | -15°C / 5°F | 40°C / 104°F | ||
A | Ammonia | 0-50ppm | 0-1000ppm | -20°C / -4°F | 40°C / 104°F | |
Construction | ||||||
Electrical | Flammable (0-100%LEL) 3 wire mV bridge 2.9-3.5V, 0.7W 200mA constant current |
Toxic & Oxygen 2 wire loop powered 4-20mA (plus screen) 16-30Vdc, O.9W |
Junction Box Earth continuity plate BK4 terminal block (4 way) 4 x 0.5mm2 (20AWG) to 2.5mm (14AWG) 1 x M20, 1 x 3/4" NPT, 1 x 1/2" NPT |
|||
Material | Polyphenylene Sulphide (PPS) | Polyphenylene Sulphide (PPS) | Fire retardant GFP | |||
Weight | 190g | 185g (205g Oxygen) | 600g | |||
Applicable standards | This product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN60079-29-1, Toxic to EN445544 (H2S only) | |||||
Environmental | ||||||
IP rating | IP65 standard, IP66 with weather protection in accordance with EN60529:1992 | |||||
Operating temperature | Dependent upon gas type and certification | |||||
Operating humidity range | Continuous: 20-90% RH (non condensing), Intermittent: 10-99% RH (non condensing) | |||||
Operating pressure | 90-110kPa | |||||
Storage conditions | Instrument -40°C to +50°C (-40°F to +122°F) |