1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Searchline Excel Plus Open Path Infrared Gas Detector, TX SS M25 - SLXL-PSMGTX

Item #:
SLXL-PSMGTX
Brand:
Honeywell Analytics
$6,396.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Searchline Excel Plus Open Path Infrared Gas Detector, TX SS M25 - SLXL-PSMGTX

Honeywell Analytics Searchline Excel Plus Open Path Infrared Gas Detector, TX SS M25 - SLXL-PSMGTX

$6,396.00

SLXL-PSMGTX Searchline Excel Plus Open Path Infrared Gas Detector, TX SS M25 by Honeywell Analytics

The Searchline Excel™ Plus Flammable Hydrocarbon gas detector delivers unsurpassed uptime with robust detection in some of the harshest conditions.

MAXIMIZE SAFETY COVERAGE EVEN IN MINIMAL VISIBILITY

Ensure optimal fire and gas safety by deploying cutting-edge optical gas detection that can see through even thick fog better than any other open path gas detectors whether NDIR or laser-based.

The Searchline Excel™ Plus is a medium-range gas detector designed for global oil and gas applications, upstream and downstream, onshore and offshore that protects your people, your facilities and your systems from combustible gas leaks.

ELEVATE YOUR ENVIRONMENTAL DUE DILIGENCE

The Searchline Excel™ Edge's innovative optical gas detection capabilities cover a longer range and see through even thick fog better than any other open path gas detectors whether NDIR or laser-based.

FEATURES AND BENEFITS

  • RELIABLE DETECTION: Fast response to flammable Hydrocarbon gas even in low visibility conditions. Advanced diagnostics including window clarity and alignment accuracy to enable maximum uptime and continuous site protection.
  • HEAVY DUTY OPERATION: Operates in harsh environments to maintain coverage. Advanced transmitter and receiver optics means that monitoring continues in thick fog long after other detectors cease to provide coverage.
  • LONG-RANGE MONITORING: Longest range site detection for fence line/perimeter monitoring up to 330 meters (1082 feet). Flat response over a range of target gasses; performance approved.
  • EASY TO USE: Low maintenance and calibration free. New Honeywell Fixed Platform Universal Mount and advanced alignment scope makes for easy mechanical installation.
  • AT-A-GLANCE INSTRUMENT STATUS: High Visibility LED HALO ring provides clear indication of device status. Automatic reporting with full logging of alarms, events and maintenance actions.
  • MULTIPLE OUTPUTS: Multiple outputs including 4-20mA, Relays, HART®, Modbus and Bluetooth® communication Easily integrate the Searchline Excel™ Plus into your existing network.
  • CONNECTIVITY: Incorporates Bluetooth® connectivity for simplified, non-intrusive set-up and maintenance. Just pair the Searchline Excel™ Plus with our intrinsically safe, ruggedized mobile phone; then use the Honeywell Fixed Platform App to interact with the detector.
Primary Gases (Performance approved 1, 2) Searchline Excel™ Plus will respond to a wide range of Hydrocarbon Gases as most of these gases absorb IR in the required wavelengths: Methane1, 2, Ethane1, Propane1, 2, Butane1, Pentane1, Hexane, Ethylene1, Propylene1; 1FM Performance Approved; 2DNV approved
Range 0–5 LEL.m; for ppm.m equivalents see manual
Recommended Alarm Setting Low 1 LEL.m; High 3 LEL.m; for ppm.m equivalents see manual
Recommended Minimum Alarm Setting LEL.m; for ppm.m equivalents see manual
Path Length 2 m to 120 m (6 ft to 393 ft)
Speed of Response T90 less than 3 seconds
Analog Output Signal 4–20 mA Normal operation, 1 mA Fault*, 2 mA Inhibit, 3 mA Warning, 21 mA Overrange. Linearized 0–5 LEL.m
Environmental Operating Temperature -55°C to +75°C (-67°F to 167°F). DNVGL-CG-0339 Location Class B
Storage Temperature Range -55°C to +75°C (-67°F to 167°F). DNVGL-CG-0339 Location Class B
Power Supply 24 Vdc nominal (18 Vdc to 32 Vdc)
Power Consumption (Average RMS) Transmitter: Above +30°C (+86°F) = 3.8 W; +30°C to -30°C (+86°F to -22°F) = 5.6 W; Below -30°C (-22°F) = 11.8 W
Receiver: Above +30°C (+86°F)= 3.0 W; +30°C to -30°C (+86°F to -22°F) = 4.8 W; Below -30°C (-22°F) = 7.4 W
Output Signals 4–20 mA with HART®, Fault relay, Alarm 1 relay, Alarm 2 relay, Modbus, Bluetooth® (range up to 20 m (66 ft), depends on mobile device and environmental conditions)
Relay Outputs Max. 32 Vdc/ac, max. 2 A resistive load
Humidity 0–99% Relative Humidity Non-condensing. DNVGL-CG-0339 Location Class B
Pressure 91.5-105.5 kPa (915–1055 mBar, non-compensated)
Repeatability ±0.4 LEL.m; for ppm.m equivalents see manual
Temperature Drift -40°C to +65°C (-40 °F to 149 °F) ±0.2 LEL.m @ zero
±0.5 LEL.m @3 LEL.m
Warm-up Time Less than 5 minutes (operational), less than 1 hour (fully stabilized)
Internal Battery Cell TLH-2450, 10-year lifetime (replaced only by authorized service)
Weight Searchline Excel™ Plus: Rx 6.1 kg (13.4 lb), Tx 6.0 kg (13.2 lb)
Universal Mounting Bracket: 3.1 kg (6.9 lb) Stainless Steel
Mount Plate Adaptor: 3.71 kg (8.18 lb) Stainless Steel
Dimensions Searchline Excel™ Plus: 103 mm dia x 325 mm x 180 mm (4.06 in dia x 12.8 in x 7.09 in)
Universal Mounting Bracket: 165 mm x 165 mm x 130 mm (6.5 in x 6.5 in x 5.12 in)
Mount Plate Adaptor: 210 mm x 210 mm x 127 mm (8.23 in x 8.23 in x 5 in)
Ingress Protection IP 66/67 (Type 4X, in accordance with NEMA 250); Resistance to salt mist and sulfuric atmosphere (15-60 minutes exposure to salt air/mist; 15-60 minutes to sulfuric atmosphere)
Safety Approvals cULus:
Class I, Division 1, Groups. B,C,D, T4, Ta -55°C to 75°C (-67°F to 167°F) Class II, Division 1, Groups. E,F,G, T4, Ta -55°C to 55°C (-67°F to 131°F) Class III Div. 1; Class I Zone 1 AEx db ia IIC T4 Gb, Ta -55°C to 75°C (-67°F to 167°F) Class I Zone 1 AEx db eb ia IIC T4 Gb, Ta -55°C to 75°C (-67°F to 167°F) Zone 21 AEx tb IIIC T100°C Db, Ta -55°C to 55°C (-67°F to 131°F); Um = 250 Vrms
IECEx:
IECEx ULD 18.0016X; Ex db ia IIC T4 Gb (for flameproof Ex d installations)
Ex db eb ia IIC T4 Gb (for increased safety Ex e installations) Ex tb IIIC 100°C Db
Tamb -55°C to 75°C (-67°F to 167°F); Um = 250 Vrms
Performance Approvals:
ANSI/FM/IEC/EN 60079-29-4
Functional Safety (SIL):
SIL 2 certified by TÜV (SÜD) to EN61508
Core Approvals:
EN 50270: (EMC) IEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EU
IEC/EN/UL/CSA 61010 (Electrical Safety); FCC / IC; RoHS, China RoHS

Questions & Answers