ScichemTech SCT-BEN-HARD-1 Benchtop Water Hardness Meter - SCT-108.003.19

Item #:
SCT-108-003-19
Brand:
ScichemTech
ScichemTech SCT-BEN-HARD-1 Benchtop Water Hardness Meter - SCT-108.003.19
$835.79
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
ScichemTech SCT-BEN-HARD-1 Benchtop Water Hardness Meter - SCT-108.003.19

ScichemTech SCT-BEN-HARD-1 Benchtop Water Hardness Meter - SCT-108.003.19

$835.79

SCT-108.003.19 SCT-BEN-HARD-1 Benchtop Water Hardness Meter by ScichemTech

Includes:

  • Water hardness electrode stirring type electrode holder
  • Water hardness calibration solution (B1,B2 & B23) 20 ml
  • Test cup pedestal in a solution for water hardness electrode tools for filling reference solution
  • WH - link communication software
  • RS-232 communication cable
  • Operation manual

Features:

  • SCT benchtop meter is for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
  • Electrode adopts water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
  • Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.
  • Ability to switch among eight units: mmol/l, mg/l (caco3), mg/l (cao), mmol/l (boiler) and mg/l (ca). Three options of three units: °FH France °DH Germany and °EH UK from WH-link communication software
  • Equipped with B1 B2 and B3 calibration solutions.
  • Equipped with WH-link communication software, connect testing data of meter to computer.
  • SCT benchtop meter meets: ISO9001 & CE standards.
WATER HARDNESS MEASURING RANGE 0 ~ 10 MMOL/L 0 ~ 401 MG/L(CA)
WATER HARDNESS UNITS 0 ~ 1000 MG/L(CACO3) 0 ~ 100 ºFH(FRANCE DEGREE)
WATER HARDNESS ACCURACY 0 ~ 561 MG/L(CAO) 0 ~ 56 ºDH(GERMAN DEGREE)
WATER HARDNESS TEMP. COMPENSATION 0 ~ 20 MMOL/L(BOILER) 0 ~ 70 ºEH (ENGLAND DEGREE)
WATER HARDNESS CALIBRATION SOLUTION 0.01 AND 0.1 WATER HARDNESS UNITS
WATER HARDNESS CALIBRATION MODE ±5% FS
5 ~ 50 AUTOMATIC
B1 CALIBRATION SOLUTION — 2.00×10-2 MMOL/L
B2 CALIBRATION SOLUTION — 2.00×10-1 MMOL/L
B3 CALIBRATION SOLUTION — 2.00 MMOL/L
B3CALIBRATION SOLUTION ALSO CAN BE USED FOR THE SOAKING SOLUTION OF ELECTRODE
(A)B1/B2 CALIBRATION—USING B1 AND B2 CALIBRATION SOLUTION SUITABLE FOR < 2.00×10-2 MMOL/L LOW CONCENTRATION WATER QUALITY FOR EXAMPLE, BOILER WATER.
(B)CALIBRATION—USING B2 AND B3 CALIBRATION SOLUTION SUITABLE FOR GENERAL WATER QUALITY.
TEMPERATURE MEASURING RANGE 0 ~ 60
TEMPERATURE UNITS 0.1
TEMPERATURE ACCURACY ±0.5
STORAGE DATA 128 GROUPS
COMMUNICATION CONNECTOR SERIAL NUMBER OF MEASURING VALUE, MEASURING VALUE, UNITS, TEMPERATURE,
ATC OR MTC, DATE, TIME AND CALIBRATION WAY.
COMMUNICATION CONNECTOR RS232
POWER DC9V
DIMENSION AND WEIGHT (160×190×70)MM/750G
QUALITY CERTIFICATION ISO9001:2000 AND CE
AMBIENT TEMPERATURE (5~35)
AMBIENT HUMIDITY ≤85%RH