- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RAE Systems Touchpoint Plus Wireless Multi-Channel Controller, AC power, 2.4GHz, 12 relays, Battery, MODBUS - TPPLWAANNSNBRT
Item #:
RAE-TPPLWAANNSNBRT
Brand:
RAE Systems
Share this product:
TPPLWAANNSNBRT Touchpoint Plus Wireless Multi-Channel Controller, AC power, 2.4GHz, 12 relays, Battery, MODBUS by RAE Systems
The Touchpoint™ Plus Wireless is a multi-channel controller with a built-in wireless modem that is designed for integration with RAE Systems by Honeywell Mesh-intelligent network of connected sensors combined with traditional hard wired sensors.
The Touchpoint™ Plus Wireless is the command-and-control element of the Mesh system that gathers data and monitors alarms from Mesh-enabled toxic and flammable gas monitors. The built-in wireless modem automatically links with Mesh-enabled monitors, and the controller has built-in security safeguards to resist tampering. The Touchpoint™ Plus Wireless does have additional 8 analogue 4-20 mA inputs for combination of traditional wired products and wireless products.
- Quick and easy installation
- Simple, intuitive operation
- Rugged and reliable
- Flexible to handle a variety of data processing and communication needs
Key Features
- Built-in wireless modemfor use in Mesh networks
- Manages up to 64 channels
- Up to 15 programmable SPDT relay outputs
- RS-485 and Ethernet interface
- 8 analogue 4-20 mA inputs
- Meteorological data sensors
- IP 65 rated
Easy to Use
- Backup battery for up to 12 hours of operation depending on configuration
- Built-in data logging
- C1D2 certified
Applications
- Drilling rigs
- Petrochemical plants
- Tank farms
- Shipyards and maritime
- Steel mills
- Industrial safety
Capacity | Up to 8 channels with base unit |
Size (Wall-Mounted Version) | 426 mm x 300 mm x 156 mm (16.8" x 11.8" x 6.1") |
Housing Material | Polycarbonate ABS |
Weight | Max. 8.5 kg (18.7 lb) |
User Interface (UI) - Controller Only | |
Display | 7" color LCD touchscreen. Graphic User Interface |
Visual Indicators | LED for each channel. Green: Normal; Yellow: Fault: Inhibit; Red: Alarm |
Audible Alarm | ≥ 70dB @ 1 m (3.28 ft) |
Button | Common for reset/mute operation |
Language | English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese |
Power Supply | |
AC Power | 110/220 VAC, 50-60 Hz Manual switching |
DC Power | 18 to 32 VDC (+/-10%) Typical 24 VDC |
Power Consumption | Max. 105 W (including detector and external devices) |
Environmental | |
Operating | 10 °C to +55 °C (14 °F to +131 °F) continuous, up to 95% RH (non-condensing), IP65 certified |
Storage | Instrument -25 °C to +60 °C (-13 °F to +140 °F), up to 95% RH (non-condensing) |
4-20mA Input | 2- or 3-wire, 8 channel modules |
Relay Output | NO/C/NC changeover, 1.7 A @ 30 VDC/250 VAC, user-configurable - energized/de-energized, latching/nonlatching, time delay |
Common Inputs | Remote reset, remote inhibit |
Common Outputs | 4 powered A/V outputs for alarms and fault, 3 common alarm outputs, max 300mA per channel |
Approvals | |
Electromagnetic Compatibility and Electrical Safety | EMC/RFI (EN 50270:2015) LVD (EN 61010-1:2010) CSA-C22.2 No. 61010-1-04 UL 61010-1 (3rd Edition) and 508 |
Hazardous Location | Class I, Division 2, Group A, B, C, and D, or non-hazardous only |
Others | |
Backup Battery | 22.2 V Lithium Ion Battery, 2600 mAh capacity (12 hours for wireless system) |
Datalogging | Configuration, logged events, and data |
Communication | MODBUS TCP, WEB monitoring, and MODBUS RTU |
Radio model | RM2400 |
Radio Frequency | 2.4 GHz IEEE 802.15.4 |
Frequency Range | 2.400-2.4835 GHz |
Frequency Channels | Frequency band has 16 available channels |
Transmission Range | Up to 300 meters line of sight |
Receiver Sensitivity | Minimum of -95 dBm at 2.4 GHz |
Modulation | 802.15.4 DSSS O-QPSK |
Transmit Power | 20 dBm |
Data rate | 250 kbps |
Radio model | RM900A |
Radio Frequency | 868-868.6MHz, 902-928MHz 11 channels |
Frequency Range | 868-868.6MHz, 902-928MHz |
Frequency Channels | Frequency band has 11 available channels depending on region |
Transmission Range | Up to 300 meters line of sight |
Receiver Sensitivity | -100dBm at at 1% packet error rate for a 20 byte payload |
Modulation | 802.15.4 DSSS BPSK |
Transmit Power | 20 dBm |
Data rate | 40kbps BPSK DSSS @915MHz 20kbps BPSK DSSS @868MHz |