- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Peak Instruments AA2928 Double Beam Flame Atomic Absorption Spectrophotometer
Item #:
PI-AA2928
Brand:
Peak Instruments
Share this product:
AA2928 Double Beam Flame Atomic Absorption Spectrophotometer by Peak Instruments
The AAS is fully PC controlled with modern and compact design. They have flexible configuration and different accessories to meet variable requirements. Advance optical system can guarantee stable and reliable performance. Unique and intelligent gas control module can ensure the device safety. The AAS can test more than 70 elements including metallic and non-metallic elements, which can be used widely in petrochemistry, metallurgy, mining, geology, material analysis, food and pharmacy.
Main Features
- Automatic vertical 4/8-lamp turret supports high-performance element lamp, can be rotated 360 degrees and make sure the test accuracy and reliability is not affected by the gravity.
- Automatic burner adjustment ensures the maximum sensitivity, you can raise or lower the burner according to the reading. Flame detection enhances the device safety.
- Modular design for optical system and circuit makes the maintenance and repair simple.
- Total reflection optical system can reduce energy loss to ensure better signal-to-noise ratio and lower detection limit.
- Standard deuterium lamp background correction for all models. Standard high-performance self-absorption background correction for double beam models, and optional for the models with 8-lamp turret.
- Automatic pneumatic control module ensures the device safety and accuracy and protects the operator and device better.
- Safety protection system: flame monitoring (acetylene will be turned off automatically if there is any abnormality and show warning information), unique acetylene protector (warning information will be shown if the leak acetylene concentration is beyond the alert concentration), pressure monitoring (the flame will not work if the air or acetylene pressure is not normal, the graphite furnace will not work if the argon pressure is too high or too low), graphite tube installation self-inspection.
- Professional, automatic and easy to operate full operation RGWIN AAS software under MS window system and QA/QC function.
- Transversely heated graphite tube ensures the consistency of the gas temperature in the graphite tube, and make the sample reach the atomic temperature instantly and simultaneously, improve atomic efficiency and test accuracy, ensure that the analysis results are more accurate, reduce the requirements for furnace body and prolong lifetime.
Model |
AA2914 |
AA2918 |
AA2928 |
|
Optical System | Optical Type | Single beam |
Single beam |
Double beam |
Monochromator | Czerny-Turner type with focal lengths at 350mm |
|||
Wavelength Range | 190-900nm |
|||
Grating | Holographic diffraction grating with 1800 lines/mm |
|||
Slits | Automated slit selection 0.1,0.2,0.4,0.7,1.4,2.0 nm |
|||
Wavelength Accuracy | ±0.3 nm |
±0.2 nm |
±0.15 nm |
|
Wavelength Repeatability | ±0.1 nm |
±0.1 nm |
±0.05 nm |
|
Lamp Holder | Automated 4-lamp turret |
Automated 8-lamp turret |
||
Detector | Wide range UV sensitive photomultiplier tube |
|||
Photometric Performance | Reading Mode | Transmittance(T), Absorbance(A), Concentration(C) |
||
Photometric Range | 0-125%, -0.1-3.00A |
|||
Static Baseline Drift (Cu) | ≤0.004A/30 min |
≤0.003A/30 min |
≤0.002A/30 min |
|
Dynamic Baseline Drift (Cu) | ≤0.006A/15 min |
≤0.005A/15 min |
≤0.004A/15 min |
|
Background Correction | Deuterium (D2) Background Correction |
D2 and Self-absorption |
||
Flame Analysis | Characteristic Concentration | Cu≤0.04ug/ml |
Cu≤0.035ug/ml |
Cu≤0.02ug/ml |
Detection Limit | Cu≤0.008ug/ml |
Cu≤$0.006ug/ml |
Cu≤0.004ug/ml |
|
Repeatability (Cu) | RSD≤1% |
RSD≤0.6% |
RSD≤0.5% |
|
Acetylene Flow Control | Auto 12-level |
Auto 12-level |
Auto 12-level |
|
Air Flow Control | Auto 4-level |
Auto 4-level |
Auto 4-level |
|
Nebulizer | High efficiency glass |
|||
Burner Adjustment | Automatic up and down |
|||
Burner Head | Titanium alloy 100mm burner for air/acetylene operation |
|||
Premix Chamber | Corrosion resistant |
|||
Safety Protection | Flame sensor, gas leak sensor, gas pressure sensor |
|||
Data Processing | Software | RGWIN AAS software pacakage |
||
Analytical Method | Flame AA, Flame AE, Hydride Generation |
|||
Concentration Calculation Method | Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation |
|||
Repeated Measurement Times | 1-30 times, calculate the average, show SD and RSD value of absorbance and concentration |
|||
QA/QC Function | Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration |
|||
Report Printing | Parameter printing, resulting printing |
|||
Communication Port | Standard RS-232 |
|||
Others | Computer | External (excluded) |
||
Dimension & Weight | (W*D*H), Kg |
|||
Power Supply | 110/220V, 50/60HZ |
|||
Working Environment | Temperature 10 ~ 35 °C, Humidity≤85% |