- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
SMC PF3W7 Digital Flow Switch for Water, 3-Color Display, Integrated Display - PF3W740-N04-BT-F
Item #:
PF3W740-N04-BT-F
Brand:
SMC
Share this product:
PF3W7 Digital Flow Switch for Water, 3-Color Display, Integrated Display by SMC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90°C, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time. Further improvements include the addition of 2 screens, incorporating 3-color numerical displays which can also be rotated in both clockwise and counter-clockwise directions, thereby offering even better display visibility during operation. Available as non-grease type and with analogue output if required, the PF3W meets IP 65 enclosure protection standards and is both RoHS and CE compliant.
- Digital flow switch for water applications
- Integrated display type
- Flow rate range: 0.5-4(L/min) ~ 10-100(L/min)
- 3-color, 2-screen display
- Port sizes: 3/8, 1/2, 3/4, 1
Product contains:
- 3-Color Digital Flow SWITCH for Water
- 40 (5 to 40 L/min)
- N (NPT)
- 04 (1/2)
- B (OUT1: PNP, OUT2: PNP)
- T (Temperature Sensor)
- Lead Wire w/M8 Connector, 3m
- F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal: Temp: °F)
Model | PF3W704 |
PF3W720 |
PF3W740 |
PF3W711 |
PF3W721 |
||
Applicable fluid | Water and ethylene glycol solution with a viscosity of 3mPa•s (3 cP) or less *1 |
||||||
Detection method | Karman vortex |
||||||
Rated flow range | 0.5 to 4 L/min |
2 to 16 L/min |
5 to 40 L/min |
10 to 100 L/min |
50 to 250 L/min |
||
Display flow range | 0.35 to 5.50 L/min (Displays 0.00 when the value is below 0.35 L/min) |
1.7 to 22.0 L/min (Displays 0.0 when the value is below 1.7 L/min) |
3.5 to 55.0 L/min (Displays 0.0 when the value is below 3.5 L/min) |
7 to 140 L/min (Displays 0 when the value is below 7 L/min) |
20 to 350 L/min (Displays 0 when the value is below 20 L/min) |
||
Switch point range | 0.35 to 5.50 L/min |
1.7 to 22.0 L/min |
3.5 to 55.0 L/min |
7 to 140 L/min |
20 to 350 L/min |
||
Min. setting unit | 0.01 L/min |
0.1 L/min |
1 L/min |
2 L/min |
|||
Conversion of accumulated pulse (Pulse width = 50 ms) | 0.05 L/pulse |
0.1 L/pulse |
0.5 L/pulse |
1 L/pulse |
2 L/pulse |
||
Fluid temperature | 0 to 90 °C (No freezing and condensation) |
0 to 70 °C (No freezing and condensation) |
|||||
Display unit | L/min for real-time flow and L for accumulated flow |
||||||
Accuracy | ±3%F.S. max. Display and analogue output |
||||||
Repeatability | ±2%F.S. max *2 |
||||||
Temperature characteristics | ±5%F.S. max. (25 °C reference) |
||||||
Operating pressure range *3 | Refer to graph of operating pressure and proof pressure |
||||||
Proof pressure *3 | Refer to graph of operating pressure and proof pressure |
||||||
Pressure loss | Refer to graph of pressure loss |
||||||
Accumulated flow range *4 | 99999999.9 L |
999999999 L |
|||||
By 0.1 L |
By 0.5 L |
By 1 L |
|||||
Switch output | NPN or PNP open collector output |
||||||
Max. load current | 80 mA |
||||||
Max. applied voltage | 28 VDC |
||||||
Internal voltage drop | NPN: 1 V max. (at 80 mA load current) PNP: 1.5 V max. (at 80 mA load current) |
||||||
Response time *2 *5 | 0.5 s/1 s/2 s |
||||||
Output protection | Short circuit protection |
||||||
Output mode | Flow | Selects one of the output (hysteresis or window comparator mode), the output for the accumulated flow and the accumulated pulse output. |
|||||
Temp | Selects the output for fluid temperature (hysteresis mode or window comparator mode). |
||||||
Analogue output | Response time *6 | 0.5 s/1 s/2 s |
|||||
Voltage output | Output voltage: 1 to 5 V Output impedance: 1 kΩ |
||||||
Current output | Output current: 4 to 20 mA Maximum load impedance: 300 Ω for 12 VDC, 600 Ω for 24 VDC |
||||||
Hysteresis | Variable |
||||||
External input | Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer |
||||||
Display method | 2-screen display (Main screen: 4-digit, 7-segment, 2-colour; red/green, Sub screen: 6-digit, 11-segment, White) Display updating frequency 5 times/sec. |
||||||
Indicator light | Output 1 and 2: Orange |
||||||
Power supply voltage | 12 to 24 VDC ±10% |
||||||
Current consumption | 50 mA max. |
||||||
Environment | Enclosure | IP65 |
|||||
Operating temperature range | 0 to 50 °C (No freezing and condensation) |
||||||
Operating humidity range | Operation, Storage: 35 to 85%R.H. (No condensation) |
||||||
Withstand voltage *7 | 1000 VAC, for 1 minute between the terminals and housing |
||||||
Insulation resistance | 50 MΩ min. (with 500 VDC) between the terminals and housing |
||||||
Standards and regulations | CE marking, UL (CSA), RoHS |
||||||
Material of wetted part | PPS, SUS304, FKM, SCS13 |
PPS, SUS304, FKM |
|||||
Grease free |
|||||||
Piping port size *8 | 3/8 |
3/8, 1/2 |
1/2, 3/4 |
3/4, 1 |
11/4, 11/2 |
||
Weight | Flow switch only | 210 g |
260 g |
410 g |
720 g |
890 g |
|
With temperature sensor | 285 g |
335 g |
530 g |
860 g |
1075 g |
||
With flow adjustment valve | 310 g |
360 g |
610 g |
- |
- |
||
With temperature sensor and flow adjustment valve | 385 g |
435 g |
730 g |
- |
- |
||
With lead wire | +85 g |
Items | Specifications |
Rated temperature range | 0 to 100 °C *1 |
Setting/display temperature range | -10 to 110 °C |
Min. setting/display unit | 1 °C |
Display unit | °C |
Display accuracy | ±2 °C |
Analogue output accuracy | ±3%F.S. |
Response time | 7 s *2 |
Ambient temperature characteristics | ±5%F.S. |
Model | PF3W711 |
PF3W721 |
||
Applicable fluid | Water and ethylene glycol solution with a viscosity of 3mPas(3 cP) or less *1 |
|||
Detection method | Karman vortex |
|||
Rated flow range | 10 to 100 L/min |
30 to 350 L/min |
||
Display flow range | 7 to 140 L/min (Displays 0 when the value is below 7 L/min) |
20 to 350 L/min (Displays 0 when the value is below 20 L/min) |
||
Switch point range | 7 to 140 L/min |
20 to 350 L/min |
||
Min. setting unit | 1 L/min |
2 L/min |
||
Conversion of accumulated pulse (Pulse width = 50ms) | 1 L/pulse |
|||
Fluid temperature | 0 to 70 °C (No freezing and condensation) |
|||
Display unit | L/min for real-time flow and L for accumulated flow |
|||
Accuracy | ±3%F.S. max. Display and analogue output |
|||
Repeatability | ±2%F.S. max. *2 |
|||
Temperature characteristics | ±5%F.S. max. (25 °C reference) |
|||
Operating pressure range *3 | Refer to graph of operating pressure and proof pressure |
|||
Proof pressure *3 | Refer to graph of operating pressure and proof pressure |
|||
Pressure loss | Refer to graph of pressure loss |
|||
Accumulated flow range *4 | 999999999 L |
|||
By 1 L |
||||
Switch output | NPN or PNP open collector output |
|||
Max. load current | 80 mA |
|||
Max. applied voltage | 28 VDC |
|||
Internal voltage drop | NPN: 1 V max. (at 80 mA load current) PNP: 1.5 V max. (at 80 mA load current) |
|||
Response time *2 *5 | 0.5 s/1 s/2 s |
|||
Output protection | Short circuit protection |
|||
Output mode | Flow | Selects one of the output (hysteresis or window comparator mode), the output for the accumulated flow and the accumulated pulse output. |
||
emp. | Selects the output for fluid temperature (hysteresis or window comparator mode). |
|||
Analogue output | Response time *6 | 0.5 s/1 s/2 s |
||
Voltage output | Output voltage: 1 to 5 V, Output impedance: 1 kΩ |
|||
Current output | Output current: 4 to 20 mA Maximum load impedance: 300 Ω for 12 VDC, 600 Ω for 24 VDC |
|||
Hysteresis | Variable |
|||
External input | Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer |
|||
Display method | 2-screen display (Main screen: 4-digit, 7-segment, 2-colour; red/green, Sub screen: 6-digit, 11-segment, White) Display updating frequency 5 times/sec. |
|||
Indicator light | Output 1 and 2: Orange |
|||
Power supply voltage | 12 to 24 VDC ±10% |
|||
Current consumption | 50 mA max. |
|||
Environment | Enclosure | IP65 |
||
Operating temperature range | 0 to 50 °C (No freezing and condensation) |
|||
Operating humidity range | Operation, Storage: 35 to 85%R.H. (No condensation) |
|||
Withstand voltage | 1000 VAC, for 1 minute between the terminals and housing |
|||
Insulation resistance | 50 MΩ min. (with 500VDC) between the terminals and housing |
|||
Standards and regulations | CE marking, UL (CSA), RoHS |
|||
Material of wetted part | PPS, FKM, CPVC |
|||
Grease free |
||||
Piping port size *7 | 25 A |
30 A |
||
Weight | Without lead wire | 285 g |
340 g |
|
With lead wire | 370 g |
425 g |
Model | PF3W704 |
PF3W720 |
PF3W740 |
PF3W711 |
PF3W721 |
|
Rated flow range | 0.13 to 1.06 gal/min |
0.53 to 4.23 gal/min |
1.3 to 10.6 gal/min |
2.6 to 26.4 gal/min |
13 to 66 gal/min |
|
Instantaneous flow | Display flow range | 0.09 to 1.45 gal/min (Flow under 0.09L/min is displayed as "0.00".) |
0.45 to 5.81 gal/min (Flow under 0.45 L/min is displayed as "0.00".) |
0.9 to 14.5 gal/min (Flow under 0.9 L/min is displayed as "0.0".) |
1.8 to 37.0 gal/min (Flow under 1.8 L/min is displayed as "0.0".) |
5 to 92 gal/min (Flow under 5 L/min is displayed as "0".) |
Setting flow range | 0.09 to 1.45 gal/min |
0.45 to 5.81 gal/min |
0.9 to 14.5 gal/min |
1.8 to 37.0 gal/min |
5 to 92 gal/min |
|
Min. setting/display unit | 0.01 gal/min |
0.1 gal/min |
1 gal/min |
|||
Accumulated flow | Setting/display flow unit | 99999999.9 gal |
999999999 gal |
|||
Min. setting/diplay unit | 0.1 gal |
1 gal |
||||
Conversion of accumulated pulse | 0.01 gal/pulse |
0.05 gal/pulse |
0.1 gal/pulse |
0.5 gal/pulse |
1 gal/pulse |
Rated temperature range * | 32 to 212 °F |
Setting/display temperature range | 14 to 230 °F |
Min. setting/display unit | 1 o°F |
Items | Specifications |
|
Conductor | Nominal cross section area | AWG23 |
Outside diameter | Approx. 0.72 mm |
|
Insulator | Outside diameter | Approx. 1.14 mm |
Colours | Brown, White, Black, Blue |
|
Sheath | Outer diameter | Φ3.4 mm |