1-866-4 JJSTECH(1-866-455-7832)

Quantrol MicroVision Cooling Tower Controller, Toroidal Probe, MV Tower, Cond Bleed, 3 Selectable Timers, 3 Shelves, In/Out Ball Valves, Y-Strainer, Inj Tees, Rails - No Pumps - MVS1PD-XXX

Item #:
MVS1PD-XXX
Brand:
Quantrol
Quantrol MicroVision Cooling Tower Controller, Toroidal Probe, MV Tower, Cond Bleed, 3 Selectable Timers, 3 Shelves, In/Out Ball Valves, Y-Strainer, Inj Tees, Rails - No Pumps - MVS1PD-XXX
$2,751.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Quantrol MicroVision Cooling Tower Controller, Toroidal Probe, MV Tower, Cond Bleed, 3 Selectable Timers, 3 Shelves, In/Out Ball Valves, Y-Strainer, Inj Tees, Rails - No Pumps - MVS1PD-XXX

Quantrol MicroVision Cooling Tower Controller, Toroidal Probe, MV Tower, Cond Bleed, 3 Selectable Timers, 3 Shelves, In/Out Ball Valves, Y-Strainer, Inj...

$2,751.00

MVS1PD-XXX MicroVision Cooling Tower Controller, Toroidal Probe, MV Tower, Cond Bleed, 3 Selectable Timers, 3 Shelves, In/Out Ball Valves, Y-Strainer, Inj Tees, Rails - No Pumps by Quantrol

MicroVision Conductivity Cooling Tower Controller Standard with Toroidal Sensor Technology!

The MicroVision is a microprocessor-based conductivity controller with selectable timer and dual biocide control. Designed specifically for cooling tower applications, MicroVision comes standard with the features and functions you need for accurate monitoring and control of cooling tower water. The MicroVision is a full function controller in a compact package that won't break your budget!

Features

  • Toroidal conductivity sensor.
  • Large graphical display with large, easy to read font.
  • Statistics screen with relay run time.
  • Flow switch input.
  • (3) drum level inputs.
  • 4-20 mA isolated analog output.
  • Dry contact alarm output
  • Battery backup.
  • Selectable timer (limit, %, % post bleed with limit, and water meter).
  • Dry contact/Hall Effect water meter input.
  • Dual biocide control.
  • Bleed output supports solenoid valve or motorized ball valve.

Operating Benefits

  • Easy to use.
  • No need to recalibrate.
  • Reduced potential for fouling.
  • Easy Installation.
  • Two year warranty.
  • Large range: 0 - 9,999 μS/cm.
  • Compact size saves space and reduces freight cost.

Controls

Bleed

  • Solenoid valves, or motorized ball valves

Feed

  • Inhibitor

Biocides

  • Dual biocide with pre-bleed, lockout, inhibitor interface, and four programmable start times per biocide

Aftermarket

  • Solenoids
  • Motorized Ball Valves
  • Water Meters
  • Corrosion Coupon Racks
  • Metering Pumps (PULSAtron, XP Series)
Specifications and Model Selection
PRODUCT DESIGNATOR
Position 1, 2 & 3
MVS = MicroVision Toroidal Conductivity Cooling Tower Controller
VOLTAGE
Position 4
1 = 115 volt
2 = 230 volt (no prewired power cord or relays available)
POWER WIRING
Position 5
X = Conduit connections (required for 230 VAC)
P = Prewired power cord and pigtails
PANELS
Position 6
X = No Panel and No Flow assembly
F = Flow assembly, No Panel
A = Standard Panel & Flow Assembly
B = Panel & Flow Assy, 1 Pump Mount, strainer, sensor tee, inj tee & rails
C = Panel & Flow Assy, 2 Pump Mount, strainer, sensor tee, 2 inj tees & rails
D = Panel & Flow Assy, 3 Pump Mount, strainer, sensor tee, 3 inj tees & rails
SUFFIX CODE
Position 7, 8 & 9
XXX = Suffix Code
750 = 3/4" Back Flow Check Valve
PC025 = 25 Feet (7.6m)
PC050 = 50 Feet (15.2m)
PC075 = 75 Feet (22.8m)
PC100 = 100 Feet (30.4m)

Engineering Data Controller
Enclosure: NEMA 4X / IP65
Power Supply: 90VAC / 50/60Hz / 5A
250 VAC / 50/60Hz / 5A
Control Output: 5 Amps max
Display: LCD
Set Point Range: 0 - 9,999 μS/cm
Languages: English
Spanish
Portuguese

Engineering Data Flow Switch
Maximum Temperature: 122°F / 50°C
Maximum Pressure: 125 PSI (8.6 BAR)
Activate Flow Rate: Approximately 1 GPM / 3.78 LPM
Materials of Construction: PVC and Glass filled Polypropylene

Engineering Data Sensor
Maximum Temperature: 122°F / 50°C
Temperature Compensation Range: 32°F - 122°F / 0°C - 50°C
Maximum Pressure: 125 PSI (8.6 BAR)
Sensor Type: Toroidal
Cable Length, Standard: 15' / 4.5m
Cable Length, Maximum: 100' / 30.5 m
Thread Size: 0.5" Standard thread-Excludes Tee and Reducer
Maximum Outside Diameter: 1.5" / 38mm-Excludes Tee and Reducer
Materials of Construction: Virgin Polypropylene

Questions & Answers