1-866-4 JJSTECH(1-866-455-7832)

Quantrol MicroVision EX Cooling Tower Controller, Toroidal Probe, Standard Panel, Conductivity Control, ORP, 6 Timers, PULSAlink Communications - MVECOXXPA-EXX-XXX

Item #:
MVECOXXPA-EXX-XXX
Brand:
Quantrol
Quantrol MicroVision EX Cooling Tower Controller, Toroidal Probe, Standard Panel, Conductivity Control, ORP, 6 Timers, PULSAlink Communications - MVECOXXPA-EXX-XXX
$3,226.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Quantrol MicroVision EX Cooling Tower Controller, Toroidal Probe, Standard Panel, Conductivity Control, ORP, 6 Timers, PULSAlink Communications - MVECOXXPA-EXX-XXX

Quantrol MicroVision EX Cooling Tower Controller, Toroidal Probe, Standard Panel, Conductivity Control, ORP, 6 Timers, PULSAlink Communications - MVECOXXPA-EXX-XXX

$3,226.00

MVECOXXPA-EXX-XXX MicroVision EX Cooling Tower Controller, Toroidal Probe, Standard Panel, Conductivity Control, ORP, 6 Timers, PULSAlink Communications by Quantrol

MicroVision EX is a microprocessor-based conductivity, pH, and ORP controller, with the features and functions you need for accurate monitoring and control of cooling tower water that won't break your budget!

Features

  • Toroidal conductivity sensor.
  • One-point calibration.
  • Large easy to read color display.
  • Lockable front cover.
  • Multiple level security codes.
  • Up to 10 digital inputs.
  • Optional 4-20 mA analog outputs and inputs.
  • Dry contact alarm output.
  • Battery backup.
  • Optional Make-up conductivity control with a toroidal sensor.
  • USB data logging is standard: Up to 2 years of data logging, Upload/Download program settings.
  • Upgrades to the Operating System.
  • Optional Ethernet interface.

Operating Benefits

  • Easy installation.
  • Easy programming based on MicroVision simplicity.
  • Toroidal conductivity probe.
  • No need to recalibrate conductivity probe.
  • Reduced potential for fouling.
  • Two year warranty.
  • Wide control range: 0 - 9,999 μS/cm.
  • Compact size saves space and reduces freight cost.

Controls

Bleed

  • Solenoid valves, or motorized ball valves

pH and ORP Control

  • Pumps, solenoid valves, or motorized ball valves

Up to 6 Selectable Timer Relays

  • Limit timer
  • Percent timer
  • % post bleed with limit timer
  • Water meter pulse timer
  • Biocide control timer, with prebleed, lockout, and conductivity minimum
  • 4-20mA input, pH, or ORP set point control
  • Alarm output

Aftermarket

  • Solenoids
  • Motorized Ball Valves
  • Water Meters
  • Corrosion Coupon Racks
  • Metering Pumps (PULSAtron, XP Series)
Specifications and Model Selection
Model
Control Parameters
Relays
Timers
Probes
USB
4-20mA Inputs
4-20mA Outputs
Digital Inputs
MVECXXX Conductivity
4
3
1
0 to 1
0 to 1
5
MVEC5XX Conductivity
5
4
1
0 to 1
0 to 1
5
MVECPXX Conductivity and pH
8
6
2
0 to 2
0 to 4
10
MVECOXX Conductivity and ORP
8
6
2
0 to 2
0 to 4
10
MVECPOX Conductivity, pH and ORP
8
5
3
0 to 2
0 to 4
10
MVECPOM Conductivity, Make-Up, pH and ORP
8
5
4
0 to 2
0 to 4
10

Engineering Data Digital Inputs
Digital Inputs
Input 1
Inputs 2 to 4
Input 5
Inputs 6 & 7
Inputs 8, 9 and 10
Function
Flow Switch
Drum Level
Water Meter
Water Meter
Water Meter
Dry Contact
Hall Effect

Engineering Data Controller
Enclosure: IP65
Temperature Range: 122°F / 50°C
Power Supply: 100 VAC - 240 VAC / 50/60Hz / 8A
Control Output: 8 Amps max
Display: Multicolor graphical LCD
Set Point Range: 0 - 9,999 μS/cm
0 - 14 pH
-2000 - + 2000mV
Set Point Types: Rising or Falling
Languages: English
Spanish
Portuguese

Engineering Data Sensor
Maximum Temperature: 122°F / 50°C
Flow Switch Activate Flow Rate: Approx. 1 GPM / 3.78 LPM
Conductivity Temp. Comp. Range: 32°F - 122°F / 0°C - 50°C
Maximum Pressure: 125 PSI (8.6 BAR)
Sensor Type: Toroidal Conductivity
Standard industrial pH and ORP sensors