Quantrol MicroTrac Series Tower Controllers with Toroidal Probe, Bleed & Selectable Feed, Flow Assembly, Panel - MTC1PTA-XXX

Item #:
MTC1PTA-XXX
Brand:
Quantrol
Quantrol MicroTrac Series Tower Controllers with Toroidal Probe, Bleed & Selectable Feed, Flow Assembly, Panel - MTC1PTA-XXX
$1,168.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Quantrol MicroTrac Series Tower Controllers with Toroidal Probe, Bleed & Selectable Feed, Flow Assembly, Panel - MTC1PTA-XXX

Quantrol MicroTrac Series Tower Controllers with Toroidal Probe, Bleed & Selectable Feed, Flow Assembly, Panel - MTC1PTA-XXX

$1,168.00

MTC1PTA-XXX MicroTrac Series Tower Controllers with Toroidal Probe, Bleed & Selectable Feed, Flow Assembly, Panel by Quantrol

The MicroTrac is a microprocessor based feed and bleed toroidal conductivity controller designed to control conductivity and feed inhibitor in cooling tower systems. Featuring innovative toroidal sensor technology, the MicroTrac provides an economical control platform that is not susceptible to sensor fouling and never requires calibration! The MicroTrac toroidal conductivity sensor is factory calibrated for the life of the probe eliminating routine calibrations saves you valuable service time and money. By design, the MicroTrac toroidal conductivity sensor has no exposed electrodes, which means that there is nothing to wear out or foul. When installed according to the manufacturer's instructions, the need for routine sensor removal and cleaning is virtually eliminated.

The MicroTrac measures the conductivity of the cooling tower recirculating water via a toroidal conductivity sensor. The controller activates two independent relay outputs based on bleed and a selectable feed mode of operation. The MicroTrac conductivity controller has a 0 - 9,999 μS/cm range, making it ideal for other applications as well, such as rinse, industrial process, wastewater, etc.

Features

  • Selectable rising or falling setpoint for open or closed loop control.
  • Water meter pulse timer.
  • Percent timer.
  • % post bleed timer.
  • Limit timer.

Operating Benefits

  • Easy to use.
  • No need to recalibrate.
  • Reduced potential for fouling.
  • Easy Installation.
  • Two year warranty.
  • Large range: 0 - 9,999 μS/cm.
  • Simple user interface.

Controls

Timers

  • Water Meter Pulse Timer
  • Percent Timer
  • % Post Bleed Timer
  • Limit Timer

Aftermarket

  • Solenoids
  • Motorized Ball Valves
  • Water Meters
  • Corrosion Coupon Racks
  • Metering Pumps (PULSAtron, XP Series)
Specifications and Model Selection
PRODUCT DESIGNATOR
Position 1, 2 & 3
MTC = MICROTrac Toroidal Conductivity Cooling Tower Controller
VOLTAGE
Position 4
1 = 115 volt
2 = 230 volt (no prewired power cord or relays available)
RELAY & POWER WIRING
Position 5
X = Prewired power cord & Liquid-Tight relay connections
L = Liquid-Tight connections only (required for 230 volt)
P = Prewired power cord and relays
SENSOR TEE
Position 6
X = Standard (no tee)
T = Sensor Tee with 3/4" inlet/outlet connections
FLOW SWITCH
Position 7
X = Suffix Code
F = Flow Switch with 3' cable
L = Standard Flow Assembly (no panel)
A = Standard Panel & Flow Assembly
B = Deluxe Panel & Flow Assy, 1 Pump Mount, in/out ball valves, strainer, inj tee & rails
SUFFIX CODE
Position 7, 8 & 9
XXX = Suffix Code
750 = 3/4" Back Flow Check Valve
PC025 = 25 Feet (7.6m)
PC050 = 50 Feet (15.2m)
PC075 = 75 Feet (22.8m)
PC100 = 100 Feet (30.4m)

Engineering Data Controller
Enclosure: NEMA 4X / IP65
Power Supply: 90VAC / 50/60Hz / 5A
250 VAC / 50/60Hz / 5A
Control Output: Line Voltage @240VA per Relay
(2 Amps @ 120VAC)
Display: LCD
Set Point Range: 0 - 9,999 μS/cm
Set Point Differential (Hystersis): Fixed 5% below the set point

Engineering Data Flow Switch
Maximum Temperature: 122°F / 50°C
Maximum Pressure: 125 PSI (8.6 BAR)
Activate Flow Rate: Approximately 1 GPM / 3.78 LPM
Materials of Construction: PVC and Glass filled Polypropylene

Engineering Data Sensor
Maximum Temperature: 122°F / 50°C
Temperature Compensation Range: 32°F - 122°F / 0°C - 50°C
Maximum Pressure: 125 PSI (8.6 BAR)
Sensor Type: Toroidal
Cable Length, Standard: 15' / 4.5m
Cable Length, Maximum: 100' / 30.5 m
Thread Size: 0.5" Standard thread-Excludes Tee and Reducer
Maximum Outside Diameter: 1.5" / 38mm-Excludes Tee and Reducer
Materials of Construction: Virgin Polypropylene