1-866-4 JJSTECH(1-866-455-7832)

Casella Insight Plug-in for Microdust Pro Real Time Dust Monitor

Item #:
Insight-E
Brand:
Casella
Casella Insight Plug-in for Microdust Pro Real Time Dust Monitor
$295.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Casella Insight Plug-in for Microdust Pro Real Time Dust Monitor

Casella Insight Plug-in for Microdust Pro Real Time Dust Monitor

$295.00

Discontinued


Insight-E Insight Plug-in for Microdust Pro Real Time Dust Monitor by Casella

The Casella Microdust Pro real Time Dust Monitor is now able to download to the Casella Insight Database Management System software program.

Stored data in the memory of the Microdust unit can be transferred to Insight for viewing, graphing and making final reports all in a single unified database software package that is easy to use and manipulate.

This Plugin can be installed with any others that are available to link all instrument measurements together for a complete industrial hygiene report.

Key Benefits

  • Download results to single software package
  • Include specific calibration corrections for dust other types
  • See when high concentration levels occurred
  • Apply exclusion zones to graph to recalculate overall concentration value
  • Save individual calibration certificates for all instruments in use with forward reminders
  • Allocate measurements to specific locations or people
  • Incorporate real time readings from MDP with results from Casella pumps

Applications

Casella Insight can be used to store downloaded results from single or multiple Microdust monitors. All result sets are searchable by start date and time. Change graph scaling and color schemes to suit required report. Include real time dust results with other gravimetric personal sampling pump measurements for complete picture of hazard. Export table of results to external spreadsheets for further data processing and manipulation. Easily create professional reports and save in a wide variety of popular formats such as pdf, rtf, xls, etc.
Measurement
Sensing Technique Forward light scattering (12 to 20°) using 880 nm infra red source.
Measuring Range 0.001 - 2,500 mg/m3 over four ranges 0 - 2.5, 0 - 25, 0 - 250 and 0 - 2500 mg/m3.
Active range may be fixed or auto ranging.
Resolution 0.001 mg/m3.
Zero Stability Typically <2 μg / m3 /°C.
Span Stability ±0.7% of reading /°C.
Operating Temp Range 0 to 50° C (non condensing).
Storage Temp Range -20 to +55° C (non condensing).
Power Supply
Instrument Power Consumption Approx. 100 mA.
Battery 4 x AA / MN1500 cells Alkaline or rechargeable Nickel Cadmium.
Operating Run Time Alkaline Batteries (2700 mAh), typically >20 hours
Rechargeable NiCd cells (950 mAh), typically >9 hours
Battery Charging Internal NiCd fast charger circuitry.
Charge termination based on Negative delta V detection with additional time-out protection.
Charger must be disabled for dry cell operation.
Charge Rate Fast charge rate 450 mA,
Standby charge rate 55 mA approx.
Power adapter (-PC18) Universal with input voltage range 100 - 240 VAC, 47 - 63 Hz.
Output 12 VDC at 0.8 A.
Supplied with connectors suitable for USA, UK, European and Australian mains outlet sockets.
The instrument may be powered continuously from the external power adapter.
Physical
Display 128 x 64 pixel LCD Graphics panel with backlight.
Keypad 7 key tactile membrane
Weight Instrument with probe: 0.97 kg.
Complete kit in carry case: 4.5 kg
Dimensions Instrument H x W x D: 245 x 95 x 50mm.
Probe: 35 mm x 290 mm total length.
Carrying case H x W x D: 135 x 490 x 370 mm.
Displayed Values
Current Concentration Represents the rolling average of instan taneous dust concentration over a user selectable time period from 1 to 60 sec.
Time Weighted Average Representing the average value since switch on or reset.
Max Value Representing the maximum instantaneous value since switch on or reset. (Instantaneous values are updated every second)
Scrolling Graph Graph mode provides unique indication of variations in dust concentration.
Selectable timebase periods of 100 sec, 200 sec, 15 mins, 60 mins, Y-axis range may be autoranging or fixed.
Factory Calibration Factory calibrated using traceable isokinetic techniques and ISO 12103-1 A2
Fine test dust (Arizona Road Dust equivalent).
Four user defined calibration settings to suit specific dust types or monitoring applications.
Routine Calibration Easy software calibration for Zero and Span setting.
Confirmation of Factory calibration point using optical reference filter.
Data Logger
Internal Memory 64 k EEPROM providing over 15,700 data points.
Example Capacities Logging every 5 seconds: 21 hours 48 mins
Logging every minute: 10 days 21 hours
Logger Interval Adjustable from 2 to 600 seconds.
Recorded Values Average concentration over logging interval.
Maximum and Average values for the entire logging period are saved at the end of each logging run.
Serial Interface RS232 up to 38,400 baud.
IrDa (Future expansion).
Analogue Output 0 - 2.5 V DC FSD, 500 Ω output impedance.
Digital output (only when Alarm is selected) 2.5 V Alarm On
0 V Alarm Off.

Questions & Answers