- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Transmission Risk Air Monitor-V2, white, with first year SW license included - HTRAM-V2-W
Item #:
HTRAM-V2-W
Brand:
Honeywell Analytics
Share this product:
HTRAM-V2-W Transmission Risk Air Monitor-V2, white, with first year SW license included by Honeywell Analytics
A cost-effective monitor for use in schools, restaurants, and other small-to-mediumsized buildings that alerts users when conditions are present that may increase the risk of exposure to airborne viral transmission.
Classrooms, restaurants, and buildings with outdated HVAC and ventilation systems can foster environments where the risk of airborne virus transmission could increase. Honeywell proprietary technology that monitors CO2 levels, coupled with user-controlled settings to account for human activity levels in an indoor area, provides users with a portable, cost- effective, and user-friendly solution that alerts when conditions are present that may increase the risk of exposure to airborne viral transmission.
Research conducted by scientists at the University of Colorado1 has shown that real-time monitoring of indoor ambient air can be an indicator of increased risk of airborne viral transmission, utilizing different levels of risk-based factors such as CO2 concentration levels and the type of human activity in the area.
Using this guidance and Honeywell algorithms, we identified air quality conditions that are driven by common activities and variables such as average room size, number of people present, breathing rate, and duration. The device comes with three pre-programmed indoor activity settings: low activity (movie theaters, libraries, and classrooms), medium activity (restaurants, offices, small clinics), and high activity (gyms, indoor arenas, recreation centers) and is recommended for coverage of 800-1000 square feet. For each setting, the monitor provides indications using a traffic light pattern (green, yellow, or red) and a sound alarm so users can be aware of conditions that may increase the risk of airborne transmission based on detectable CO2 levels.
FEATURES AND BENEFITS
- The monitor comes with a user manual and USB charging cable. AC adapter sold separately.
- Made of alloy and plastic, the monitor's sleek, lightweight design makes it easy to carry for real-time monitoring anywhere.
- Red (high), yellow (medium), and green (low) for at-a-glance estimation of risk levels.
SPECIFICATIONS | |||
CHARACTERISTIC | PARAMETER | ||
Dimensions (H × W × D) | 80 mm × 80 mm × 22 mm [3.1 in × 3.1 in × 0.87 in] | ||
Weight | 140 g | ||
Housing materials | Aluminum alloy | ||
Display | TFT | ||
Input voltage | 5 V | ||
Input current | 1 A | ||
Battery | Lithium-ion rechargeable battery 10-hour battery time |
||
Battery capacity | 2,600 mAh | ||
Operating temperature & humidity | 0°C to 40°C, 0% RH to 90% RH | ||
USB port | Micro USB | ||
SENSOR RANGE | |||
DESCRIPTION | DETECTION RANGE | ||
CO2 (NDIR) | 400 ppm to 2000 ppm, up to 10,000 ppm extended range | ||
Temperature | -20°C to 60°C or -4°F to 140°F | ||
Humidity | 0% RH to 100% RH | ||
DEVICE INDICATION | |||
GREEN | YELLOW | RED | |
Low Activity Setting | <800 ppm 0.043% infection risk |
800 ppm 0.043% infection risk |
1100 ppm 0.051% infection risk |
Medium Activity Setting | <700 ppm 3.40% infection risk |
700 ppm 3.40% infection risk |
1000 ppm 5.41% infection risk |
High Activity Setting | <500 ppm 7.32% infection risk |
500 ppm 7.32% infection risk |
800 ppm 25.25% infection risk |
Custom Setting | The end user can also choose custom settings on the device to set the alarm threshold levels based on the user's parameters and local, regional and state requirements. Note: If custom settings are used, the user is solely responsible for validating that those alarm settings meet their specific requirements. | ||
Recommended Action | - | Open windows Turn on HVAC fan Move out of room Additional actions as needed |
Ventilate room immediately Reduce activities Move out of room Additional actions as needed |
Alarm | - | One beep | Two beeps |