- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Mini Sanitation System - HISANI
Item #:
HISANI
Brand:
Hanna Instruments
Share this product:
Mini Sanitation System
Free & Total Chlorine Range | 0.00 to 5.00 mg/L |
pH Range | 0.00 to 14.00 pH |
Temperature Range | 5.0 to 75.0°C |
mV Range | 0 to 2000 mV |
Free & Total Chlorine Resolution | 0.01 mg/L |
pH Resolution | 0.01 pH |
Temperature Resolution | 0.1°C |
mV Resolution | 1 mV |
Free & Total Chlorine Accuracy | ±8% ±0.05 mg/L |
pH Accuracy | ±0.05 pH |
Temperature Accuracy | ±0.5°C |
mV Accuracy | ±1 mV |
Free & Total Chlorine Minimum Detectable Level | 0.05 mg/L |
Input Impedance Minimum Detectable Level | 1012 Ohm |
Free & Total Chlorine Calibration | 1 point |
pH Calibration | 1 or 2 point |
Free & Total Chlorine Sampling Rate | adjustable from 3 to 90 minutes |
pH Sampling Rate | adjustable from 3 to 120 seconds |
Free & Total Chlorine Dosage | proportional with 4-20 mA output |
pH Dosage | ON/OFF with relay or proportional with 4-20 mA output |
Free & Total Chlorine Delta | selectable from 0.1 to 5 mg/L |
pH Delta | selectable from 0.1 to 2 pH (hysteresis adjustable from 0.05 to 2 pH) |
Recorder Output | 0-10 mV, 0-100 mV, 4-20 mA or 0-20 mA |
Serial Communication | RS485 port, galvanically isolated |
Baud Rate | 1200, 2400, 4800, 9600 bps |
Data Logging | up to 3500 data series |
GSM Communication | 2 programmable cellular phone numbers, alarm & information SMS using the HI 504900 module (optional) |
Alarm Relay | SPDT contact with 5A, 230 V resistive load |
Dosing Relay | SPDT contact with 5A, 230 V resistive load |
System Error | SPDT contact with 5A, 230 V resistive load |
Inlet Pressure | 0.07 to 4 bar with no external pressure regulator (for pressure exceeding 4 bar an external pressure regulator is required) |
Sample Flow | 100 to 300 mL/min |
Sample Temperature | 5 to 40°C (41 to 104°F) |
Sample Inlet Connection | 12 mm (1/2") tubing diameter |
Drain Connection | 10 mm (3/8") bar fitting |
Power Supply | 115 Vac or 230 Vac; 50/60 Hz; 20 VA (See Chart) |
Enclosure | NEMA-4X standard, molded fiberglass polyster with transparent Lexan window |
Dimensions | 318 x 267 x 159 mm (12.5 x 10.5 x 6.25") |
Weight | 5 kg (11 lb.) without reagents |