- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Industrial Grade pH Controller with Single Set point and Proportional Dosage, 230V - HI9910-2
Item #:
HI9910-2
Brand:
Hanna Instruments
Share this product:
HI9910-2 Industrial Grade pH Controller with Single Set point and Proportional Dosage, 230V by Hanna Instruments
HI 9910 is a pH controller with a single set point for proportional dosage of acid or alkaline solutions. Any pH electrode ending in a BNC connector can be directly attached to the controller. The proportional control can be fine tuned through two dials on the front panel. The time cycle is adjustable from 0 to 90 seconds and the proportional band from 0.0 to 2.0 pH. Coarse and fine as well as offset and slope trimmers make accurate setting and calibration easy and convenient. A pump or electrovalve can be wired directly to the controller and be powered through the terminals.
The HI 9910 also provides for an alarm relay. The alarm is activated when the measurements stray away from the set point by a predetermined value in the 0.5 to 2.5 pH range. A maximum dosing time from 1 to 10 minutes can also be set, after which the alarm is activated to warn of an abnormality. The alarm can be configured in either normally-closed or normally-opened state. HI 9910 also provides an isolated output signal which is user selectable between 0-20 or 4-20 mA. A dial on the front panel renders manual temperature compensation fast and easy.
For automatic temperature compensation, hook up a three wire Pt100 to the controller. To speed up wiring, the HI 9910 comes with extractable terminal modules. Once wired up, the compartment containing the connections is protected behind a fire-retardant ABS panel. Several LED's show whether the set point or alarm relays are activated from a distance.
Order Information:
HI 9910 is supplied complete with instructions.
Range | 0.00 to 14.00 pH |
Resolution | 0.01 pH |
Accuracy @ 20°C | ±0.02 pH |
Calibration | through "OFFSET" and "SLOPE" trimmers (max. ±1.5 pH for offset and 80% to 110% for slope) |
Temperature Compensation | automatic from 0 to 50°C with Pt100 probe or manual from -10 to 80°C |
Setpoint | from 0.00 to 14.00 pH with "COARSE" and "FINE" trimmers with "ACID" or "ALK" (alkaline) selection |
mA Output | user selectable 0 to 20 mA or 4 to 20 mA over the 0-14 pH range with isolated output |
Proportional Control |
pH is user adjustable from 0.0 to 2.0 and time cycle from 0 to 90 seconds |
Alarm Contact | terminals can be configured as normally open or normally closed (isolated output max. 2A, max. 240V, resistive load, 1,000,000 strokes). The alarm is activated if pH varies by more than user selectable interval (0 to 2 pH) from set point or due to overdosage |
Dosing Terminals | relay terminals (115 to 240V, max.2A,1,000,000 strokes) are activated when pH exceeds the set point with “ACID” dosage or falls below the set point with “ALK” selection (alkaline dosage) |
Power Supply | ±10% 115 VAC or 230 VAC; 50/60 Hz |
Environment | -10 to 50°C (14 to 122°F); RH max 95% non-condensing |
Case Material | fiber-reinforced, self-extinguishing ABS |
Dimensions | 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) |
Weight | 1.6 kg (3.5 lb.) |