- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Industrial Grade pH Digital Controllers Wall Mounted with Matching Pin, Analog Output, 230V - HI21211-2
Item #:
HI21211-2
Brand:
Hanna Instruments
Share this product:
HI21211-2 Industrial Grade pH Digital Controllers Wall Mounted with Matching Pin, Analog Output, 230V by Hanna Instruments
The HI 21 controllers are simple to operate, microprocessor-based pH process controllers packed with features. With HI 21 quick one, two or three point calibration at pH 4.01, 7.01 and 10.01 comes standard and you can choose from ON/OFF, proportional and PID control to save on chemicals. These instruments have a differential input, extending electrode life by eliminating ground loop current through the reference.
Password protection prevents unauthorized modifications in settings or calibration. The Fail Safe Alarm System protects the HI 21 against the pitfalls of process control, like power interruption or line failure.
Wiring the controllers is simple with extractable terminal modules. A host of self-testing features and user-friendly functions make HI 21 a great value.
For more flexibility and better resolution for chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Some HI 21 models are equipped with a bi-directional RS485 port, which allows remote control of the instrument from a PC.
- Control through analog output (single set point) or relay
- Fully customizable
- RS485 interface
- Differential input for ground loop protection
- Automatic three point pH calibration
- Last calibration data
- Automatic Temperature Compensation
- Password protection
- Fail Safe Alarm System
- Overdosing safeguard
Order Information:
Each HI 21 model is supplied with instructions.
Choose your configuration
HI 21111-1 single setpoint, on/off control, analog output, 115V
HI 21111-2 single setpoint, on/off control, analog output, 230V
HI 21211-1 dual setpoint, on/off control, analog output, 115V
HI 21211-2 dual setpoint, on/off control, analog output, 230V
HI 21221-1 dual setpoint, on/off and proportional control, analog output, 115V
HI 21221-2 dual setpoint, on/off and proportional control, analog output, 230V
HI 21222-1 dual setpoint, on/off and proportional control, RS485 output, 115V
HI 21222-2 dual setpoint, on/off and proportional control, RS485 output, 230V
HI 21523-1 control through analog output, on/off and proportional control, analog output and RS485, 115V
HI 21523-2 control through analog output, on/off and proportional control, analog output and RS485, 230V
pH Range | 0.00 to 14.00 pH |
Temperature Range | -9.9 to 120°C |
pH Resolution | 0.01 pH |
Temperature Resolution | 0.1°C |
pH Accuracy @ 20°C | ±0.02 pH |
Temperature Accuracy @ 20°C | ±0.5°C |
Input Impedance | 1012 Ohm |
pH Calibration | automatic, one, two or three point, at pH 4.01, 7.01, 10.01 |
Temperature Compensation | automatic (with Pt100 probe) or manual from -9.9 to 120°C |
Analog Output | 0 to 1 mA, 0 to 20 mA, 4 to 20 mA; 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC |
Digital Output | RS485 |
Relays 1 and 2 | electromechanical relay SPDT contact outputs, 5A-250 VAC, 5A - 30 VDC (resistive load) (HI 211YZ and HI 212YZ), fuse protected: 5A, 250V fast fuse |
Alarm Relay | electromechanical relay SPDT contact output, 5A - 250 VAC, 5A - 30 VDC (resistive load) fuse protected: 5A, 250V, 250V fast fuse |
Power Supply Input | ±5V (for amplified electrodes) |
Power Supply | 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz |
Power Consumption | 15 VA |
Over Current Protection | 400 mA, 250V, fast fuse |
Environment | 0 to 50°C (32 to 122°F); RH max. 85% non-condensing |
Protection | IP 54 |
Dimensions | 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) |
Weight | 1.4 kg (3.1 lb.) |