- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Pronto EC Meter, Range 0.00 to 19.99 µS/cm, 115V - HI983304-01
Item #:
HI983304-01
Brand:
Hanna Instruments
Share this product:
HI983304-01 Pronto EC Meter, Range 0.00 to 19.99 µS/cm, 115V by Hanna Instruments
HI 983304-01 is specifically designed for use in demineralized and deionized water.
When placed at the output of any demineralization system, the visual alarm will be activated once the demineralizing equipment is exhausted. This exclusive feature will ensure maximum system efficiency with minimum investment.
This meter is supplied with an HI 7631/2 direct 2-pin probe with 2 m (6.6') cable and a ½" thread for flow-thru mounting. This probe is also equipped with a temperature sensor to automatically compensate measurements against temperature changes from 5 to 50°C (41 to 122°F).
When operating in the measurement mode, HI 983304-01’s red LED will alert the user as soon as the reading is 1 µS/cm over the setpoint.
- Specifically designed for demineralization and deionization applications
- Water resistant enclosure
- External 12 VDC power supply for continuous monitoring
- Selectable setpoint and LED alarm
- Automatic Temperature Compensation
- Molded hook for easy installation
Order Information:
HI 983304-01 (115V) and HI 983304-02 (230V) are supplied with HI 7631/2 EC/TDS probe, calibration screwdriver, 12 VDC adapter and instructions.
Range | 0.00 to 19.99 µS/cm |
Resolution | 0.01 µS/cm |
Accuracy | ±2% F.S. |
Calibration | manual, 1 point through trimmer |
Temperature Compensation | automatic, 5 to 50°C (41 to 122°F) with ß=2.4%/°C |
Setpoint | 1.00 to 5.00 µS/cm |
Alarm | red LED (blinks when measurement differs from setpoint by ±1.00 µS/cm |
EC Probe | HI 7631/2 with 2 m (6.6') cable and ½" thread (included) |
Power Supply | 12 Vdc power adapter (included) |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 86 x 110 x 43 mm (3.4 x 4.3 x 1.7") |
Weight | 215 g (7.6 oz.) |