- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna pH and EC Transmitter with Galvanic Isolated Output Designed to be used with the HI 8000 Series - HI98143-22
Item #:
HI98143-22
Brand:
Hanna Instruments
Share this product:
HI98143-22 pH and EC Transmitter with Galvanic Isolated Output Designed to be used with the HI 8000 Series by Hanna Instruments
The HI 98143 series is designed to accept signals directly from a pH electrode and a conductivity probe at the same time.
Direct connection of the probes to the transmitter assure a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.
Four models are available, transmitting a 0-1 V, 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance. Compensation for the effects of temperature for EC measurements are performed by the transmitters’ Automatic Temperature Compenstion circuitry.
The transmitter can be connected to any pH or conductivity controller, recorder, PC or any data monitoring device that accepts 0 to 1 V, 0 to 4 V or 4 to 20 mA input. HI98143 is an ideal tool for applications that require the monitoring of both pH and conductivity at the same time
- Accepts pH electrode and EC probe signals simultaneously
- Direct probe connection; Assures a positive electrical connection eliminating signal loss
- Automatic Temperature Compensation (EC only)
Order Information:
HI 98143-22 with 4-20 mA isolated output (specific for the HI 8000 controllers), is supplied with instructions.
pH Range | 0 to 14 pH |
EC Range | 0 to 10 mS/cm |
pH Accuracy @ 20 °C | ±0.5% f.s. |
EC Accuracy @ 20 °C | ±2% f.s. |
pH Calibration | manual, 2 point, through offset and slope trimmers |
EC Calibration | manual, 2 point, through 0 and 5 mS/cm trimmers |
Temperature Compensation (EC) | automatic, 0 to 60°C (32 to 132°F) with ß=2%/°C |
Output (isolated) | 4-20 mA |
pH Electrode | HI 1001 pH electrode (suggested, not included), HI 1283 matching pin (not included) |
EC Probe | HI 3001 (not included) with cell constant 2.1 |
Casing | IP 54 |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 160 x 105 x 31 mm (6.3 x 4.1 x 1.2’’) |
Weight | 280 g (9.9 oz.) |