- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Dual-channel, K, J, T-Type Thermocouple Thermometer with PC Connectivity - HI93552R
Item #:
HI93552R
Brand:
Hanna Instruments
Share this product:
HI93552R Dual-channel, K, J, T-Type Thermocouple Thermometer with PC Connectivity by Hanna Instruments
HI 93552R is a dual-channel waterproof K, J, and T-type thermocouple thermometer that can switch between thermocouple types at a touch of a button.
At any time, users can switch views to see all information on either channel, display current temperature or average along with the high and low values. Users can also see the difference between the two channels simultaneously along with the high and low of the difference.
The HOLD button freezes the display to allow the user time to record readings. The °C/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.
For high accuracy, HI 93552R features a CAL button to allow the operator a simple one point calibration in an ice bath at 0°C when probe interchange occurs.
HI 93552R adds RS232 output that allows for data transfer to a PC or printer.
The instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.
- Accepts K, J, T – thermocouples
- Waterproof casing
- High/Low function
- °C to °F shifting
- HOLD function
- BEPS and low battery warning
- Battery life indicator at start-up
- Auto-off capability
- One point calibration
- Backlight display
- PC and printer compatible
Order Information:
HI 93552R is supplied with batteries, instructions and protective case.
K Range | -200.0 to 999.9°C; 1000 to 1371°C; -328.0 to 999.9°F; 1000 to 2500°F |
J Range | -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F |
T Range | -200.0 to 400.0°C; -328.0 to 752.0°F |
K Resolution | 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C); 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F); 0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F) |
J Resolution | 0.1°C (-200.0 to 999.9°C); 0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F) |
T Resolution | 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F) |
Accuracy | ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5° (outside); (for 1 year, excluding probe error) |
Probe | HI 766 series K-type thermocouple (not included) |
PC Connection | RS232 serial port |
Battery Type / Life | 1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off: after 60 minutes of non-use (HI 93542); selectable after 8 or 60 minutes of non-use (HI 93552) (can be disabled for all models) |
Environment | -10 to 50°C (14 to 122°F); RH max 100% |
Dimensions | 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’) |
Weight | 235 g (8.3 oz.) |