- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Dual-input, K-Type Thermocouple Thermometer with CAL Button - HI93532N
Item #:
HI93532N
Brand:
Hanna Instruments
Share this product:
HI93532N Dual-input, K-Type Thermocouple Thermometer with CAL Button by Hanna Instruments
Conditions often require the measurement of two samples at the same time. The HI 93532N features two built in channels for two K-type probe connectors.
This thermometer displays current temperature along with the high and low values in either channel. You can also see the difference between the two channels simultaneously with the high and low of the difference.
The HOLD button freezes the display to allow the user time to record readings.
The HI 93532N features a user-activated backlight for low or no light conditions. The CAL button allows the operator to perform a simple one point calibration in an ice bath at 0°C when probe interchange occurs.
The instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.
- Dual input
- High accuracy ±0.2%
- Waterproof casing
- High/Low function
- °C to °F shifting
- HOLD function
- BEPS and low battery warning
- Battery life indicator at start-up
- Auto-off capability
- Backlight display
- One point calibration
Order Information:
HI 93532N is supplied with batteries and instructions.
Range | -200.0 to 999.9°C; 1000 to 1371°C; -328.0 to 999.9°F; 1000 to 2500°F |
Resolution | 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (outside); 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F); 0.3°F (-328.0 to 250.0°F); 1°F (outside) |
Accuracy | ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5° (outside); (for 1 year, excluding probe error) |
Probe | HI 766 series K-type thermocouple (not included) |
Battery Type / Life | 1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off after 60 minutes of non-use (can be disabled) |
Environment | -10 to 50°C (14 to 122°F); RH max 100% |
Dimensions | 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’) |
Weight | 235 g (8.3 oz.) |