1-866-4 JJSTECH(1-866-455-7832)

Hanna Dual-channel, K, J, T-Type Thermocouple Thermometer - HI93542

Item #:
HI93542
Brand:
Hanna Instruments
Hanna Dual-channel, K, J, T-Type Thermocouple Thermometer - HI93542
$272.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Dual-channel, K, J, T-Type Thermocouple Thermometer - HI93542

Hanna Dual-channel, K, J, T-Type Thermocouple Thermometer - HI93542

$272.00

Discontinued


HI93542 Dual-channel, K, J, T-Type Thermocouple Thermometer by Hanna Instruments

HI 93542 is a dual-channel waterproof K, J, and T-type thermocouple thermometer that can switch between thermocouple types at a touch of a button.

At any time, users can switch views to see all information on either channel, display current temperature or average along with the high and low values. Users can also see the difference between the two channels simultaneously along with the high and low of the difference.

The HOLD button freezes the display to allow the user time to record readings. The °C/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.

The instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.

  • Accepts K, J, T – thermocouples
  • Waterproof casing
  • High/Low function
  • °C to °F shifting
  • HOLD function
  • BEPS and low battery warning
  • Battery life indicator at start-up
  • Auto-off capability

Order Information:

HI 93542 is supplied with batteries, instructions and protective case.

K Range -200.0 to 999.9°C; 1000 to 1371°C;
-328.0 to 999.9°F; 1000 to 2500°F
J Range -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F
T Range -200.0 to 400.0°C; -328.0 to 752.0°F
K Resolution 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C);
0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F);
0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)
J Resolution 0.1°C (-200.0 to 999.9°C);
0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)
T Resolution 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C);
0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)
Accuracy ±0.5°C (-100.0 to 999.9°C); ±1°C (outside);
±1°F (-148.0 to 999.9°F); ±1.5° (outside);
(for 1 year, excluding probe error)
Probe HI 766 series K-type thermocouple (not included)
Battery Type / Life 1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off: after 60 minutes of non-use (can be disabled)
Environment -10 to 50°C (14 to 122°F); RH max 100%
Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)
Weight 235 g (8.3 oz.)