1-866-4 JJSTECH(1-866-455-7832)

Hanna Manual Calibration Dissolved Oxygen Meter - HI9142

Item #:
HI9142
Brand:
Hanna Instruments
Hanna Manual Calibration Dissolved Oxygen Meter - HI9142
$544.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Manual Calibration Dissolved Oxygen Meter - HI9142

Hanna Manual Calibration Dissolved Oxygen Meter - HI9142

$544.00

Discontinued


HI9142 Manual Calibration Dissolved Oxygen Meter by Hanna Instruments

The ever increasing demand for instant on-site analysis results has created a need for innovative and rugged portable, waterproof meters.

Field work can subject instrumentation to the inclemency of weather. Cold, rain, snow, dust and humidity can cause condensation to breech the housing. Once the housing has been compromised, the meter is susceptible to diminishing performance and life. The rugged, waterproof housing of the HI 9142 solves many of the problems of field use.

Calibration is performed with HI 7040 zero oxygen solution, while 100% calibration is done in air.

The polarographic probe (HI 76407/4) is accurate to 0.3 ppm and is supplied with a 4 m (13') cable that allows measurements to be taken even in hard to reach places.

  • Automatic Temperature Compensation
  • Affordable and efficient
  • DO probe and carrying case included

Order Information:

HI 9142 is supplied with HI 76407/4 probe with 4 m (13’) cable, 2 spare membranes, HI 7041S electrolyte solution (30 mL), calibration screwdriver, batteries, instructions and rugged carrying case.
HI 9142/10 is supplied with everything above but substitutes a 10 m (32.8’) probe cable for the 4 m.
HI 9142/20 is supplied with everything above but substitutes a 20 m (65.6’) probe cable for the 4 m.

O2 Range 0.0 to 19.9 mg/L (ppm)
Temperature Range -5.0 to 50.0ºC (32.0 to 122.0ºF)
O2 Resolution 0.1 mg/L (ppm)
Temperature Resolution 0.1°C (1ºF)
O2 Accuracy (@20°C) ±1.5% F.S.
Temperature Accuracy (@20°C) ±0.2°C (±1ºF) (excluding probe error)
Calibration manual, at one or two points (zero and slope)
Temperature Compensation automatic, 0 to 50°C (32 to 122°F)
Probe HI 76407/4 polarographic DO probe with internal temperature sensor, DIN connector and 4 m (13’) cable
Battery Type / Life 1.5V AAA (3) / approximately 1,000 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight 300 g (10.6 oz.)

Datasheets & User Manuals

Questions & Answers