- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna ISO Bench Turbidity Meter With Extended Range, Dot Matrix LC, 230V - HI88713-02
Item #:
HI88713-02
Brand:
Hanna Instruments
Share this product:
HI88713-02 ISO Bench Turbidity Meter With Extended Range, Dot Matrix LC, 230V by Hanna Instruments
The HI 88713 turbidity bench meter meets and exceeds the requirements of the ISO 7027 standard.
HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.
Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.
The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.
The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.
- Graphic display, backlit LCD
- Two, three, four or five point calibration
- GLP features
- Log up to 200 records
- Contextual help and tutorial mode
- USB PC connectivity
Order Information:
HI 88713-01 (115V) and HI 88713-02 (230V) are supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.
FNU Mode Range | 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU |
FAU Mode Range | 10.0 to 99.9; 100 to 4000 FAU |
NTU Ratio Mode Range | 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC |
NTU Non-Ratio Mode Range | 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC |
FNU Mode Resolution | 0.01; 0.1; 1 FNU |
FAU Mode Resolution | 0.1; 1 FAU |
NTU Ratio Mode Resolution | 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC |
NTU Non-Ratio Mode Resolution | 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC |
FNU Mode Accuracy @25°C | ±2% of reading plus stray light |
FAU Mode Accuracy @25°C | ±10% of reading |
NTU Ratio Mode Accuracy @25°C | ±2% of reading plus stray light / ±5% of reading above 1000 NTU |
NTU Non-Ratio Mode Accuracy @25°C | ±2% of reading plus stray light |
Range Selection | automatic |
Repeatability | ±1% of reading or stray light, whichever is greater |
Stray Light | < 0.1 NTU (0.05 EBC) |
Light Detector | silicon photocell |
Light Source | IR LED |
Method | ISO 7027 Method |
Measuring Mode | normal, average, continuous. |
Turbidity Standards | <0.1, 15, 100, 750 FNU and 2000 NTU |
Calibration | two, three, four or five-point calibration |
Log Memory | 200 records |
PC Connectivity | USB |
Environment | 0°C (32°F) to 50°C (122°F); max 95% RH non-condensing |
Power Supply | 12 Vdc power input |
Dimensions / Weight | 230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.) |