- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna pH/ORP/ISE Graphic LCD pH Benchtop Meter with Two Input Channels - HI3222-01
Item #:
HI3222-01
Brand:
Hanna Instruments
Share this product:
HI3222-01 pH/ORP/ISE Graphic LCD pH Benchtop Meter with Two Input Channels by Hanna Instruments
HANNA’s HI 3222 benchtop instrument features up to five point pH calibration with a choice of five custom buffers and seven standard buffers.
HI 3222 features an interactive user support interface that assists you before, during and after measurement. On-screen tutorials guide users through set-up, calibration and measurement while context sensitive help of any screen is available at a push of a button. The help screen includes language specific assistance for menu parameters, calibration, logging, contact and accessory information for your instrument.
This instrument features HANNA’s exclusive Calibration Check™, a diagnostics system that ensures accurate pH readings every time. By alerting users of potential problems during the calibration process, the Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration. Throughout the calibration process, users are guided step-by-step by the on-screen tutorial. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.
HI 3222 is equipped with two input channels for simultaneous measurements. Having these two channels eliminates the need for swapping probes and recalibrating.
This meter can measure using ORP electrodes (pH channel input), thanks to it's capability to measure mV with a resolution up to 0.1 mV. The HI 3222 can use ISE electrodes in the ppm scale (pH channel input) and provides a choice of measurement units (ppb, ppm, molarity, weight/volume %). The electrode type and unit selection capability and the ISE calibration in up to five calibration standard solutions make these instruments very useful for a large range of concentration solutions measurements.
- One or two input channels
- pH Calibration Check™
- Five point pH calibration with seven standard and five custom buffers
- Stability, interval and log on demand logging
- Up to 400 log on demand records and 600 automatic logging records
- Messages on the graphic LCD for an easy and accurate calibration
- Multi-language support
- GLP features
- PC interface via USB
Order Information:
HI 3222-01 (115V) and HI 3222-02 (230V) are supplied with HI 1131B pH electrode, HI 7662-T temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 electrode cleaning solution sachet (2), HI 7071S electrolyte solution (30 mL), 12 VDC adapter and instructions.
pH Range | -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH |
mV Range | ±2000 mV |
ISE Range | 1.00 E-7 to 9.99 E10 concentration (choice of units) |
Temperature Range | -20.0 to 120.0 °C (-4.0 to 248.0°F) |
pH Resolution | 0.1; 0.01; 0.001 pH |
mV Resolution | 0.1 mV |
ISE Resolution | 3 digits 0.01; 0.1; 1; 10 concentration |
Temperature Resolution | 0.1°C (0.1°F) |
pH Accuracy (@ 20ºC/68ºF) | ±0.01; ±0.002 pH |
mV (@ 20ºC/68ºF) | ±0.2 mV |
ISE (@ 20ºC/68ºF) | ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) |
Temperature (@ 20ºC/68ºF) | ±0.2°C (±0.4°F) (excluding probe error) |
pH Calibration | up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers |
ISE Calibration | up to five point calibration, six standard solutions (in units selected) |
Slope Calibration | from 80 to 110% |
pH Calibration Check™ | yes |
Relative mV Offset Range | ±2000 mV |
pH Temp. Compensation | manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) |
Input Channels | 2 |
pH Electrode | HI 1131B pH electrode with glass body, BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | HI 7662-T temperature probe, stainless steel with 1 m (3.3’) cable (included) |
Logging | log on demand 400 samples |
Lot Logging | 5, 10, 30 seconds; 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes (max 600 samples) |
PC Connectivity | opto-isolated USB (with optional HI 92000 software) |
Input Impedance | 1012 Ohms |
Power Supply | 12 VDC adapter (included) |
Environment | 0-50°C (32 to 122°F) RH max 55% non-condensing |
Dimensions | 235 x 207 x 110 mm (9.2 x 8.14 x 4.33”) |
Weight | 1.8 kg (4.1 lbs.) |