- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Calibration Check™ pH/ORP/Temperature Benchtop Meter with extended pH range - HI2223-02
Item #:
HI2223-02
Brand:
Hanna Instruments
Share this product:
HI2223-02 Calibration Check™ pH/ORP/Temperature Benchtop Meter with extended pH range by Hanna Instruments
A properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age, poor maintenance or improper handling, any electrode in time will lose its integrity.
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.
A dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.
The HI 2223 is a pH benchtop meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition, it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.
The second feature is to detect if the calibration buffer solution is contaminated. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.
This meter can measure using ORP electrodes (pH channel input), due to it’s capability to measure mV with a resolution up to 0.1 mV.
HI 2223 also features five point calibration with seven standard buffers, Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function, measurements are stored in non volatile memory and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.
- pH Calibration Check™
- On-screen electrode condition and response time
- Up to five point calibration with seven standard buffers
- Diagnostic alerts through icons
- Automatic Temperature Compensation
- Log up to 500 samples
- GLP features
- PC interface via US
Order Information:
HI 2223-01 (115V) and HI 2223-02 (230V) are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 cleaning solution sachet, HI 7071S electrolyte solution (30 mL), 12 VDC adapter and instructions.
pH Range | –2.00 to 16.00 pH; –2.000 to 16.000 pH |
mV Range | ±999.9 mV; ±2000 mV |
Temperature Range | – 20.0 to 120.0 °C |
pH Resolution | 0.01 pH; 0.001 pH |
mV Resolution | 0.1mV(± 999.9mV); 1mV(± 2000mV) |
Temperature Resolution | 0.1 °C |
pH Accuracy | ±0.01 pH; ±0.002 pH |
mV Accuracy | ±0.2mV(± 999.9mV) |
Temperature Accuracy | ± 0.2 °C (excluding probe error) |
pH Calibration | Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
Temperature Compensation | Manual or automatic from -20 to 120°C |
Temperature Probe | HI 1131P glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe |
PC Connection | USB |
Data Logging | 500 points |
Dimensions | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3") |
Weight | 1.3 kg (2.9 lb.) |