- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna 0.001 Resolution pH/ORP/ISE/°C Benchtop Meter - HI2216-01
Item #:
HI2216-01
Brand:
Hanna Instruments
Share this product:
HI2216-01 0.001 Resolution pH/ORP/ISE/°C Benchtop Meter by Hanna Instruments
The HI 2216 is a pH, ORP, ISE meter with five point pH calibration and 0.001 pH resolution.
This instrument provides GLP capabilities to allow for the storage and retrieval of all data regarding pH, ORP, and ISE calibration.
HI 2216 can perform measurements using ORP electrodes in the mV scale and ISE electrodes in the ppm scale through the pH channel input. A relative mV feature is also provided.
- Up to five point pH calibration with seven standard buffers
- Up to two point ISE calibration with five standard solutions
- 0.001 pH resolution
- Calibration expiration reminder
- GLP features
- Automatic Temperature Compensation
- Manually log up to 200 records and interval log up to 500 records
- PC interface via USB
Order Information:
HI 2216-01 (115V) and HI 2216-02 (230V) is supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), HI 700661 cleaning solution sachet, 12 VDC adapter and instructions.
pH Range | –2.0 to 16.0 pH; –2.00 to 16.00 pH; –2.000 to 16.000 pH |
mV Range | ±999.9 mV (ORP); ±2000 mV (ORP) |
ISE Range | 0.001 to 19990 ppm |
Temperature Range | –20.0 to 120.0 ºC (-4.0 to 248.0ºF) |
pH Resolution | 0.1 pH; 0.01 pH; 0.001 pH |
mV Resolution | 0.1 mV (±999.9 mV); 1 mV (±2000 mV) |
ISE Resolution | 0.001 (to 1.999 ppm); 0.01 (to 19.99 ppm); 0.1 (to 199.9 ppm); 1 (to 1999 ppm); 10 (to 19990 ppm) |
Temperature Resolution | 0.1 ºC |
pH Accuracy (@ 20ºC/68ºF) | ±0.1 pH; ±0.01 pH; ±0.002 pH |
mV Accuracy (@ 20ºC/68ºF) | ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV) |
ISE Accuracy (@ 20ºC/68ºF) | ±0.5% FS |
Temperature Accuracy (@ 20ºC/68ºF) | ±0.2ºC (excluding probe error) |
Relative mV Offset | ±2000 mV |
pH Calibration | automatic, up to five point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and two custom buffers |
ISE Calibration | automatic, one or two points with five available buffers (0.1, 1, 10, 100, 1000 ppm) |
Temperature Compensation | manual or automatic (with HI 7662 probe) from –20.0 to 120.0 ºC (-4.0 to 248.0ºF) |
pH Electrode | HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included) |
Input Impedance | 1012 ohm |
PC Connectivity | opto-isolated USB |
Data Logging | log on demand, 200 records; autologging, 500 records |
Logging Interval | stability logging (“StAb”) 5, 10, 30 seconds; 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes |
Power Supply | 12 VDC adapter (included) |
Environment | 0 to 50°C (32 to 122°F); RH max 95% |
Dimensions | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) |
Weight | 1.3 Kg (2.9 lb.) |