1-866-4 JJSTECH(1-866-455-7832)

Hanna pH/ORP Benchtop Meter with Three Point Calibration - HI2213-02

Item #:
HI2213-02
Brand:
Hanna Instruments
Hanna pH/ORP Benchtop Meter with Three Point Calibration - HI2213-02
$594.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna pH/ORP Benchtop Meter with Three Point Calibration - HI2213-02

Hanna pH/ORP Benchtop Meter with Three Point Calibration - HI2213-02

$594.00

Discontinued


HI2213-02 pH/ORP Benchtop Meter with Three Point Calibration by Hanna Instruments

The HI 2213 is a pH and temperature benchtop meter. HI 2213 can also measure oxidation reduction potential (ORP) in the mV range. A relative mV feature is provided.

Calibration can be performed at up to three-points using five standard and two custom buffers.

This instrument features manual or automatic temperature compensation with the HI 7662 temperature probe. GLP (Good Laboratory Practice) feature provides data consistency. A calibration reminder can be set to alert the user, that too much time has elapsed since the last pH calibration and a new one should be performed.

  • Up to three point pH calibration with five standard buffers or two custom
  • ORP measurement
  • Relative mV readings
  • GLP features
  • Calibration expiration reminder
  • Automatic Temperature Compensation

Order Information:

HI 2213-01 (115V) and HI 2213-02 (230V) are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), HI 700661 cleaning solution sachet, 12 VDC adapter and instructions.

pH Range –2.00 to 16.00 pH
mV Range ±699.9 mV; ±2000 mV
Temperature Range –20.0 to 120.0 ºC
pH Resolution 0.01 pH
mV Resolution 0.1 mV; 1 mV
Temperature Resolution 0.1 ºC
pH Accuracy @ 20°C ±0.01 pH
mV Accuracy @ 20°C ±0.2 mV; ±1 mV
Temperature Accuracy @ 20°C ±0.2ºC (excluding probe error)
pH Calibration automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
Relative mV Offset Range ±2000 mV
pH Calibration automatic, up to three points with five standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01), and two custom buffers
Temperature Compensation manual or automatic from –20.0 to 120.0 ºC (-4.0 to 248.0ºF)
pH Probe HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Input Impedance 1012 ohm
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
Weight 1.3 kg (2.9 lbs.)

Questions & Answers