- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna pH/ORP Benchtop Meter with Three Point Calibration - HI2213-01
Item #:
HI2213-01
Brand:
Hanna Instruments
Share this product:
HI2213-01 pH/ORP Benchtop Meter with Three Point Calibration by Hanna Instruments
The HI 2213 is a pH and temperature benchtop meter. HI 2213 can also measure oxidation reduction potential (ORP) in the mV range. A relative mV feature is provided.
Calibration can be performed at up to three-points using five standard and two custom buffers.
This instrument features manual or automatic temperature compensation with the HI 7662 temperature probe. GLP (Good Laboratory Practice) feature provides data consistency. A calibration reminder can be set to alert the user, that too much time has elapsed since the last pH calibration and a new one should be performed.
- Up to three point pH calibration with five standard buffers or two custom
- ORP measurement
- Relative mV readings
- GLP features
- Calibration expiration reminder
- Automatic Temperature Compensation
Order Information:
HI 2213-01 (115V) and HI 2213-02 (230V) are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), HI 700661 cleaning solution sachet, 12 VDC adapter and instructions.
pH Range | –2.00 to 16.00 pH |
mV Range | ±699.9 mV; ±2000 mV |
Temperature Range | –20.0 to 120.0 ºC |
pH Resolution | 0.01 pH |
mV Resolution | 0.1 mV; 1 mV |
Temperature Resolution | 0.1 ºC |
pH Accuracy @ 20°C | ±0.01 pH |
mV Accuracy @ 20°C | ±0.2 mV; ±1 mV |
Temperature Accuracy @ 20°C | ±0.2ºC (excluding probe error) |
pH Calibration | automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01) |
Relative mV Offset Range | ±2000 mV |
pH Calibration | automatic, up to three points with five standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01), and two custom buffers |
Temperature Compensation | manual or automatic from –20.0 to 120.0 ºC (-4.0 to 248.0ºF) |
pH Probe | HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included) |
Input Impedance | 1012 ohm |
Power Supply | 12 VDC adapter (included) |
Environment | 0 to 50°C (32 to 122°F); RH max 95% |
Dimensions | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) |