- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
BW Technologies GasPoint Transmitter with H2S Sensor Unit, Modbus Compatible
Item #:
GP-HD
Brand:
BW Technologies
Share this product:
GP-HD GasPoint Transmitter with H2S Sensor Unit, Modbus Compatible by BW Technologies
The GasPoint transmitter provides a 4-20 mA output signal that can be connected to any control system (DCS, PLC, etc.). With advanced sensor technology and microcontroller based operation, the GasPoint provides continuous monitoring of hazardous gases.
- The GasPoint transmitter can accept any GasPoint sensor type: electrochemical, catalytic or IR (infrared). All plug-in sensor assemblies are field-interchangeable.
- Full function sensor integrity test (auto) continuously advises gas sensing ability and life ended
- Non-intrusive, one-person calibration with auto zero and auto span
- Equipped with three 5-amp relay contacts, two gas alarm relays (low/high) and fault alarm. Field-selectable normally energized/de-energized and latching/non-latching alarm relay functions.
- Two backlit alphanumeric LCDs advise all environmental and gas hazard conditions as well as instrument and sensor status
- Remote toxic/oxygen sensors can be installed over 3,900 ft./ 1,100 m away; combustible sensors over 1,550 ft./475 m. Kit can be installed at any time.
- Alarm setpoints displayed on demand, simply press the external button
- Field programmable alarm levels
- Backlight (auto) in low light conditions and alarm
- Extensive fault diagnostics
- 2-way digital communication using MODBUS module
Display advises:
- Gas type monitored
- Continuous (%LEL, %v/v or ppm) readout of gas concentration
- Alarm level and type encountered - LOW/HIGH or FAULT
- When sensor has failed its automatic daily self-test
- "Sensor Replacement" and "Sensor Expired" indications
- When to apply gas during calibration
Special Features:
- Change gases monitored in the field at any time. The GasPoint Transmitter will recognize the sensor installed and test and reset itself to that sensor type.
- No junction box connection required.
- Daily sensor integrity test (auto) monitors sensor operation, length of time sensor has been in service and advises when sensor requires replacement.
- GasPoint allows you to set or change calibration time and gas alarm setpoints in the field.
- Select or modify the measuring range using a simple dipswitch.
- The optional plug-in MODBUS expansion module provides an addressable communications interface (1-247).
Part Number: GPHD
MONITOR: | 3-wire, 4-20 mA gas transmitter with advanced microcontroller-based circuitry |
Power Input: | 12 to 32 volts DC |
Output Current: | Normal Operation: Isolated linear 4-20 mA output Calibration Mode: Steady 3 mA (auto reset to normal operation) Fault Mode: 2 mA signal (and less) |
Power Consumption: | Toxic Versions: 40 mA at 24 VDC Combustible Version: 100 mA at 24 VDC Relays: 50 mA per relay at 24 VDC |
SENSORS: | Plug-in, smart sensors |
Detection Type: | Combustible gases: catalytic or IR; Toxic gases and Oxygen: electrochemical |
Self-Test: | Automatic daily self-test of sensor integrity and sensor life |
Relative Humidity: | 5 to 95% RH non-condensing |
Drift: | Zero: <5% per year; Span: <10% per year |
CALIBRATION: | Non-intrusive, via pushbutton Auto zero and auto span |
DISPLAYS: | Two backlit liquid crystal displays LCD 1 3-digit continuous readout of the gas present (ppm, % LEL or %v/v) LCD 2 Alphanumeric diagnostic status display |
Alarm Setpoints: | Two setpoints: user-selectable |
RELAY CONTACTS: | Three SPDT relays; 5 amps at 250 VAC LOW/HIGH: Field selectable for normally energized/de-energized and latching/non-latching |
TRANSMISSION RANGES: | Relay contacts not considered. |
CONTROLS: | Calibration: Non-intrusive via external pushbutton Alarm Setpoints: Simple up/down pushbuttons with LCD readout of setpoints |
PHYSICAL: | Size: 6.8 x 7 x 4.3 inches / 17 x 17.8 x 10.8 cm (approx.) Weight: 4.85 lb. / 2.2 kg (approx.) |
Transmitter: | Nema 4, explosion-proof, anodized aluminum enclosure with mounting flanges |
Sensor: | Stainless steel enclosure |
WARRANTY: | Instrument: 2 years non-prorated; Sensor: 2 years full replacement warranty |
Gas Monitoring Specifications | Detectable Accuracy | LCD Increment | Temperature Range | Units | Programmed Measuring Ranges |
Combustibles - Catalytic | 1% | 1 | -40 to +90°C / -40 to +194°F | %LEL | 0-100* |
Combustibles - Infrared | 1% | 1 | -40 to +70°C / -40 to +150°F | %LEL | 0-100* |
H2S | 0.25 ppm | 1 | -40 to +50°C / -40 to +122°F | ppm | 0-20, 0-50, 0-100*, 0-500 |
CO | 1 ppm | 1 | -20 to +50°C / -4 to +122°F | ppm | 0-50, 0-100, 0-500*, 0-1,000 |
NH3 | 1 ppm | 1 | -10 to +50°C / +14 to +122°F | ppm | 0-50*, 0-100, 0-500, 0-1,000 |
HCN | 0.1 ppm | 0.1 | -20 to +50°C / -4 to +122°F | ppm | 0-20.0*, 0-50.0, 0-100 |
NO2 | 0.1 ppm | 0.1 | -20 to +50°C / -4 to +122°F | ppm | 0-50.0*, 0-10.0, 0-20.0, 0-99.9 |
SO2 | 1 ppm | 1 | -20 to +50°C / -4 to +122°F | ppm | 0-100*, 0-50, 0-20, 0-10 |
O2 | 0.01% | 0.1 | -20 to +50°C / -4 to +122°F | %v/v | 0-30.0%* |
Cl2** | 0.1 ppm | 0.1 | -20 to +50°C / -4 to +122°F | ppm | 0-5.0*, 0-10.0, 0-100.0 |