- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RKI Instruments Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC - GD-K7D2-H2S-24B
Item #:
GD-K7D2-H2S-24B
Brand:
RKI Instruments
Share this product:
GD-K7D2-H2S-24B Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC by RKI Instruments
The GD-K7D2 is RKI’s workhorse sample draw assembly for use with a wide variety of electrochemical sensors for toxic gas detection. It is designed for simple servicing in that the sensor and pump can be easily replaced in less than one minute each. The GD-K7D2 is normally supplied with a 115 VAC pump, which requires local AC power, and the sensor signal output is 4-20 mA (24 VDC, 2 wire loop). A 24 VDC pump is also available, in which the head uses a 3 wire connection to a controller or PLC. The compact design of the unit requires minimum mounting space and the front removal cover allows for installation and ease of service in tight spaces. Easy to install, operate, and maintain, the GD-K7D2 is RKI’s most popular sample draw head for toxic gases.
Features
- Built-in sampling pump
- Complete sensor and pump in one housing
- Quick installation wall brackets
- Easy sensor and pump removal for maintenance
- Front removal cover
- Built-in flow indicator and low flow alarm
- Quick response sensors
- Over 30 sensors to choose from
- Built-in battery for bias of sensors
- Optional NEMA 4X housing available
Applications
- Semiconductor
- Chemical Processing
- Laboratory
- Manufacturing
*Please note we can only ship RKI products to customers within the United States
Detection Principle | Electrochemical cell |
Sampling Method | Sample drawing type |
Sample Flow Rate | 0.5 lpm |
Signal Transmission | Analog transmission (4-20 mA) Two wire digital transmission |
Alarm Response Time | Approximately 30 seconds when exposed to gas concentration of 1.6 times alarm level for most gases (Same as T60) |
Self Diagnosistic Function | Low flow relay contact |
Operating Conditions | 0 - 40°C, 30 - 85% R. H. |
Power Requirements | 24 VDC or 115 VAC versions available |
Applicable Cable | Shielded cable 3C, 1.25 sq (18 gauge) for power Shielded twisted one pair cable, 1.25 sq (18 gauge) for signal |
Enclosure | Wall mounting, non-explosion proof |
Dimensions | 2.75" (W) x 6.45" (H) x 6.0" (D), approximately 4 lbs 70 mm (W) x 164 mm (H) x 153 mm (D), approximately 1.8 kg |
Ammonia (NH3) | 0 - 75.0 ppm |
Arsine (AsH3 ) | 0 - 0.20 ppm |
Boron Trichloride (BCl3) | 0 - 15.0 ppm |
Carbon Monoxide (CO) | 0 - 300 ppm |
Chlorine (Cl2) | 0 - 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 - 1.00 ppm |
Chlorine Trifluoride (ClF3) | 0 - 1.00 ppm |
Diborane (B2H6) | 0 - 0.3 ppm |
Fluorine (F2) | 0 - 6.0 ppm |
Hydrogen Chloride (HCl) | 0 - 15.0 ppm |
Hydrogen Fluoride (HF) | 0 - 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
Nitric Oxide (NO) | 0 -100.0 ppm |
Nitrogen Dioxide (NO2) | 0 - 15.0 ppm |
Ozone (O3) | 0 - 1.0 ppm |
Phosphine (PH3) | 0 - 1.0 ppm |
Silane (SiH4) | 0 - 15.0 ppm |
Sulfur Dioxide (SO2) | 0 - 30.0 ppm |