1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC - GD-K7D2-H2S-24B

Item #:
GD-K7D2-H2S-24B
Brand:
RKI Instruments
RKI Instruments Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC - GD-K7D2-H2S-24B
$1,522.50
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC - GD-K7D2-H2S-24B

RKI Instruments Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC - GD-K7D2-H2S-24B

$1,522.50

Discontinued


GD-K7D2-H2S-24B Detector/Transmitter, Sample Draw, Hydrogen Sulfide(H2S) 0-30 PPM, 24 VDC by RKI Instruments

The GD-K7D2 is RKI’s workhorse sample draw assembly for use with a wide variety of electrochemical sensors for toxic gas detection. It is designed for simple servicing in that the sensor and pump can be easily replaced in less than one minute each. The GD-K7D2 is normally supplied with a 115 VAC pump, which requires local AC power, and the sensor signal output is 4-20 mA (24 VDC, 2 wire loop). A 24 VDC pump is also available, in which the head uses a 3 wire connection to a controller or PLC. The compact design of the unit requires minimum mounting space and the front removal cover allows for installation and ease of service in tight spaces. Easy to install, operate, and maintain, the GD-K7D2 is RKI’s most popular sample draw head for toxic gases.

Features

  • Built-in sampling pump
  • Complete sensor and pump in one housing
  • Quick installation wall brackets
  • Easy sensor and pump removal for maintenance
  • Front removal cover
  • Built-in flow indicator and low flow alarm
  • Quick response sensors
  • Over 30 sensors to choose from
  • Built-in battery for bias of sensors
  • Optional NEMA 4X housing available

Applications

  • Semiconductor
  • Chemical Processing
  • Laboratory
  • Manufacturing

*Please note we can only ship RKI products to customers within the United States

GD-K7D2 Specifications:
Detection Principle Electrochemical cell
Sampling Method Sample drawing type
Sample Flow Rate 0.5 lpm
Signal Transmission Analog transmission (4-20 mA)
Two wire digital transmission
Alarm Response Time Approximately 30 seconds when exposed to gas concentration of 1.6 times alarm level for most gases (Same as T60)
Self Diagnosistic Function Low flow relay contact
Operating Conditions 0 - 40°C, 30 - 85% R. H.
Power Requirements 24 VDC or 115 VAC versions available
Applicable Cable Shielded cable 3C, 1.25 sq (18 gauge) for power
Shielded twisted one pair cable, 1.25 sq (18 gauge) for signal
Enclosure Wall mounting, non-explosion proof
Dimensions 2.75" (W) x 6.45" (H) x 6.0" (D), approximately 4 lbs
70 mm (W) x 164 mm (H) x 153 mm (D), approximately 1.8 kg

Partial List Of Detectable Gases
Ammonia (NH3) 0 - 75.0 ppm
Arsine (AsH3 ) 0 - 0.20 ppm
Boron Trichloride (BCl3) 0 - 15.0 ppm
Carbon Monoxide (CO) 0 - 300 ppm
Chlorine (Cl2) 0 - 3.0 ppm
Chlorine Dioxide (ClO2) 0 - 1.00 ppm
Chlorine Trifluoride (ClF3) 0 - 1.00 ppm
Diborane (B2H6) 0 - 0.3 ppm
Fluorine (F2) 0 - 6.0 ppm
Hydrogen Chloride (HCl) 0 - 15.0 ppm
Hydrogen Fluoride (HF) 0 - 9.0 ppm
Hydrogen Sulfide (H2S) 0 -100.0 ppm
Nitric Oxide (NO) 0 -100.0 ppm
Nitrogen Dioxide (NO2) 0 - 15.0 ppm
Ozone (O3) 0 - 1.0 ppm
Phosphine (PH3) 0 - 1.0 ppm
Silane (SiH4) 0 - 15.0 ppm
Sulfur Dioxide (SO2) 0 - 30.0 ppm

Questions & Answers