- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
BW Technologies GasAlertMax 3 Gas Detector %LEL, O2, H2S
Item #:
GAMAX3-3H
Brand:
BW Technologies
Share this product:
GAMAX3-3H GasAlertMax 3 Gas Detector %LEL, O2, H2S by BW Technologies
GasAlertMax provides extraordinary cost of ownership advantages. Training and maintenance costs are minimized through automated calibration, internal plug-in sampling pump, long-life VersaPak battery power (available in local stores) and simple, one-button control. GasAlertMax is powered by two advanced microcontrollers and features plug-in electrochemical and catalytic sensors. High-output audible/visual alarms provide instant notification.
The large alphanumeric LCD shows real-time gas concentrations and the instrument's status at all times. A full-function self-test verifies sensor, circuitry and battery integrity and activates the audible/visual alarms each time the detector is activated. GasAlertMax clearly advises the hazard present - Low, High, TWA and STEL multi-gas alarm. Recorded TWA, STEL and Peak exposures can be displayed on demand.
GasAlertMax satisfies the OSHA safety regulation CFR1910.146 (Permit Required - Confined Space Entry).
Protect Yourself
- Large LCD shows real-time gas concentrations of H2S, CO, O2 and %LEL
- Internal plug-in pump for remote sampling
- LOW, HIGH, and TWA alarms with adjustable setpoints
- Equipped with plug-in, replaceable sensors
- Simple, automatic calibration procedure
- Intrinsically safe to U.S., European and Canadian standards
- Provides 95 dB tone and bright LED indication on alarm
- Compact (1.6 x 3.0 x 5.9 in / 40 x 75 x 150 mm) and lightweight (15.4 oz. / 396 g)
- Runs an entire shift on one Black & Decker VersaPak rechargeable battery (available worldwide)
- Peak values displayed on command
- Full-function self-test of: sensor/battery/circuitry integrity; and audible/visual alarms
- One VersaPak rechargeable battery, 2-port charger, 10 ft. / 3m. sampling hose, calibration hose, carrying holster, and instructions in local languages included
- Vibrating alarm and remote audible/visual alarm (110 dB) accessories available
Part Number: GAMAX33H
Auto zero: | Yes |
Calibration: | Automatic |
Backlight: | Low light (auto); alarm condition (auto); reactivation on demand |
Full function self-test: | Sensor integrity, circuitry and battery; audible/visual alarms |
Sensor: | Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL) |
User field options: | Set calibration due date, display language, enable/disable automatic O2 calibration, span concentration values, STEL calculation period, clock, calendar, enable/disable pump test, confidence beep, pass code protection, latching alarms and sensor on/off |
ALARM INDICATORS: | Clearly advise alarm levels both visually and audibly |
Visual alarm: | Flashing, wide-angled alarm lens with dual red LEDs, plus alarm LCD readout |
Audible alarm: | High-output, variable, pulsing siren 95 dB at 1 ft. / 0.3 m |
Confidence beep: | Every 5 seconds (field-selectable) |
Other: | Low battery; off warning; sensor fail; multiple gas hazard |
Remote alarm (option): | Accepts vibrating alarm or remote audible/visual alarm (110 dB) |
LCD: | Continuous, alphanumeric gas readout and status display advises: |
Gas ppm or %: | Simultaneously and continuously displays all 4 gas concentration(s) present |
TWA ppm or %: | Records and displays on demand and during alarm |
Peak ppm or %: | Records and displays peak exposure to gas and displays on demand |
Setpoints: | Displayed on activation and after calibration (auto) in ppm or % |
TESTS: | |
Full-function self-test: | Full-function self-test on activation (auto) |
Battery: | Continuous (auto) |
GENERAL SPECIFICATIONS: | Impact-resistant ABS enclosure |
Operating Temperature: | -4 to 122 oF / -20 to 50 oC (Australia -20 oC to 40 oC) |
2Temperature code: | North America (cCSAus) 132 oC(T4) at 50 oC Europe (ATEX) 184 oC at 50 oC Australia (SA) 213 oC |
Humidity: | 5% to 95% RH (non-condensing) |
EMI/RFI: | Complies with EMC Directive 89/336/EEC |
Battery type: | One 3.6 volt Black & Decker VersaPak rechargeable cell |
Battery run-time: | NiMH: up to 12 hours operation; NiCd: up to 8 hours operation |
Size: | 1.6 x 3.0 x 5.9 inches / 40 x 75 x 150 mm |
Weight: | 15.4 oz. / 396 g |
WARRANTY: | Full 2 year warranty including all sensors |
DATALOGGER OPTIONS: | User-downloadable datalogger |
Data recorder: | All events and occurrences |
Sampling rate: | Factory set at 5-second intervals |
Storage: | 4.4 months of continuous data via 32 MB Flash MMC card (64 MB cards are also available); when full, the wraparound feature replaces oldest data with most recent data |
Gas: | H2S | CO | O2 (% by vol.) | Combustibles |
Measuring Range: | 0 - 100 ppm | 0 - 500 ppm | 0 - 30.0 % | 0 - 100 % LEL |
Low alarm level1: | 10 ppm | 35 ppm | 19.5 % | 10 % |
TWA alarm level1: | 10 ppm | 35 ppm | N/A | N/A |
High alarm level1: | 15 ppm | 200 ppm | 23.5 % | 20 % |