- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece In Duct Hot-wire Anemometer - STA2
Item #:
FP-STA2
Brand:
Fieldpiece
Share this product:
STA2 In Duct Hot-wire Anemometer by Fieldpiece
The STA2 is a Hot-wire Anemometer built for the HVACR professionals' air balancing needs. The compact probe tip makes measuring air velocity directly in the duct a breeze. It's great for traversing a duct and automatically calculating CFM without the hassle and expense of a bulky hood. The 38" telescoping probe's laser etched ruling and flattened edges allows techs to locate proper measurement points within a duct, and ensures that the probe is properly aligned.
This in duct hot-wire anemometer quickly calculates CFM from air velocity and free area. And with the intuitive interface, the STA2 makes it easy to capture the correct data.
- Measures air velocity and temperature
- Calculates CFM
- Slim 38" telescoping probe for in duct traversing
- Fast response time
- Dual display for combo of real-time CFM, air velocity, or temp
- Depth and direction indicators
- Minimizes turbulence effect with time/test point averages
- Hands-free testing with stabilizing cone and magnetic hanger
Includes
- Hot-wire Anemometer - STA2
- Stabilizing Cone
- Blow-molded Case with Padding
General Specifications | |
Accuracy | Stated accuracy @ 73°F±9°F (23°C±5°C), <90%RH |
Temperature coefficient | 0.1 x (specified accuracy) per °C for 0°C to 18°C, 28°C to 50°C (32°F to 64°F, 82°F to 122°F) |
Operating environment | -4°F to 122°F (-20°C to 50°C) at <75%RH |
Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
Battery | 9V |
Battery life | 20-35 hours approx. (alkaline) |
Battery indication | battery symbol is displayed when the battery voltage drops below the operating leve |
Auto Power off | after 15 minutes of inactivity if APO is active. |
Over range | "OL" or "-OL" is displayed |
Dimensions | 7.2 in (H) x 2.5 in (W) x 1.3 in (D) [185mm (H) x 65mm (W) x 35mm (D)] |
Weight | 12 oz. (340g) including battery |
Velocity | |
Sensor type | Micro-glass bead thermistor |
Resolution | 1 fpm (0.01 m/s) |
Range | 40-3960 fpm (0.20-20.00 m/s) |
Accuracy | ± (5%+1 dgt) reading or ± (1%+1dgt) full scale |
Units | fpm, m/s, km/hr, mph |
Temperature | |
Sensor type | Thermistor |
Range | -4°F to 140°F (-20°C to 60°C) |
Resolution | 0.1°C, 0.1°F |
Accuracy | ±1.0°F for 32°F to 113°F ±2.0°F for -4°F to 32°F, 113°F to 140°F ±0.5°C for 0°C to 45°C ±1.0°C for -20°C to 0°C, 45°C to 60°C |