- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece Carbon Monoxide Detector Accessory - ACM4
Item #:
FP-ACM4
Brand:
Fieldpiece
Share this product:
ACM4 Carbon Monoxide Detector Accessory by Fieldpiece
The ACM4 is a carbon monoxide detector (CO detector) accessory head for use with Fieldpiece modular instruments. It has a fast reacting electrochemical sesor specific designed to detect carbon Monoxide (CO). Use the ACM4 to hunt down sources of potentially life-threatening, poisonous gas. And easily replace the sensor in the field when necessary.
Carbon monoxide (CO), a product of combustion is an oderless, colorless gas. Faulty combustion equipment is one source of this dangerious gas known as the "silent killer".
The ACM4 carbom monoxide detector measures CO in parts per million (ppm). Use it for walk-around tests to help pinpoint sources of CO indoors..
CO Exposure Effects
CO ppm | Effects |
9 ppm | Minimal. Max allowable concentration for eight hours (EPA and ASHRAE). |
35 ppm | Max for continuous exposure for one hour (EPA and ASHRAE). |
50 ppm | Max for eight hours (OSHA). |
100 ppm | Trips installed CO detectors. UL2034 specifies a max exposure of 100 min. |
200 ppm | In two to three hours: slight headache, tiredness, dizziness, nausea. UL2034 specifies a max exposure of 35 min. |
400 ppm | In one or two hours: frontal headaches. In three hours: life threatening. UL2034 specifies a max exposure of 15 min. |
800 ppm | In fourty five minutes: dizziness, nausea, and convulsions. |
800 ppm | In two to three hours: death. |
1600 ppm | In one hour: death. |
6400 ppm | In fifteen minutes: death. |
12800 ppm | in three minutes: death. |
The ACM4 Carbon Monoxide Detector (CO Detector) offers several features and benefits to field technicians:
- Field-replaceable sensor
- Works with any Fieldpiece expandable instrument or handle or any DMM with mVDC ranges and our detachable leads.
- Fast electrochemical sensor helps you find CO sources like cracked heat exchangers or breached flue stacks.
- Calibrate to ambient quickly with ZERO calibration pot.
- Auto Power Off (APO) to save battery life (easy to disable).
- Battery check with % of battery life left displayed.
- Use with optional AOXP2 pump for flue gas testing.
- Display measurements smoothly (average) or real-time (normal)
Includes
- ACM4 Carbon Monoxide Detector
- Calibration Screwdriver
- 9V Battery (installed)
- Operator's Manual
Sensor Type | Electrochemical (specific to CO) |
Sensor Calibration | Factory calibrated @ 205 ppm CO |
Range | 0 to 1000 ppm; 0 to 2000 ppm (less than 5 minute exposure time) |
Initial Accuracy | @ 73°F±9°F, <75% R.H. 0-15ppm ±5% reading ±1 ppm after zeroing 16-35ppm ±5% reading ±2 ppm after zeroing 36-1000ppm ±5% reading ±5ppm after zeroing |
Long Term Drift | less than 5% per year (depending on use) |
CO Air Sample Temperature Range | 32 to 105°F |
Operating Environment | 32 to 122°F (0 to 50°C); 15 to 90% R.H., non-condensing |
Storage Environment | 32 to 68°F (0 to 20°C) at <80% R.H. with battery removed from meter |
Battery | 9V |
Battery Life | 150 hours typical alkaline |
Auto Power Off | After 15 minutes. |