1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments FP-300 Paper Tape Machine, C4F6 / C5F8, 0-5.00 ppm - FP-300AGZS

Item #:
FP-300AGZS
Brand:
RKI Instruments
RKI Instruments FP-300 Paper Tape Machine, C4F6 / C5F8, 0-5.00 ppm - FP-300AGZS
$9,030.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments FP-300 Paper Tape Machine, C4F6 / C5F8, 0-5.00 ppm - FP-300AGZS

RKI Instruments FP-300 Paper Tape Machine, C4F6 / C5F8, 0-5.00 ppm - FP-300AGZS

$9,030.00

FP-300AGZS FP-300 Paper Tape Machine, C4F6 / C5F8, 0-5.00 ppm by RKI Instruments

RKI’s paper tape monitors utilize highly sensitive colorimetric tapes to achieve interference free detection at low PPB and PPM levels Ammonia, Arsine, Chlorine, Diborane, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Phosphine, Silane. The FP-300 is equipped with an easily replaceable tape. This model is equipped with a digital display showing the type of gas and concentration in PPM or PPB. The FP-300 will also display remaining tape life as well as an end of tape alarm.

The FP-300 has audible and visual alarms, as well as alarm relay contacts and 4-20mA output. A unique “tape saver mode” extends tape life in applications where high background gas levels may be present.

The FP-300 meets and exceeds OSHA and NIOSH compliance requirements, and does not respond to interfering gases (hydrocarbons, alcohols, solvents, CO, etc.) that may be present in industrial/manufacturing environments.

Features:

  • Small and compact
  • Highly sensitive and ideal for low gas concentrations (ppb detection)
  • Interference-free detection
  • Easy detection tape replacement with plug-in cassette
  • Tape remainder display and tape end warning alarm provided
  • Easily transportable

Applications:

  • Scrubbers
  • Environmental Monitoring
  • Semiconductor Fabs
  • Manufacturing
  • Detecting uncaptured gas from scrubber

*Please note we can only ship RKI products to customers within the United States

FP-300 Specifications:
Detection principle Photoelectric photometry method using tape cassette
Detection tape Plug-in cassette
Accuracy Within ±20% + 1 of indication
Operation time of the tape 1 month(with no alarm) Tape remainder display, Tape end warning
Alarm functions Latching(standard) or self reset Lamp(Caution: Yellow, Warning: Red) and buzzer
Self-diagnosis Sensor failure, Low flow, Tape failure, Tape end warning, Failure of tape setting, System error
External output signal 4-20mA(300 Ω at maximum load resistance)
Operating temperature & humidity 5~30°C 30~90%RH(nom-condensing)
Power supply & power 24VDC ±10% for panel mounting 100VAC, 110VAC, 117VAC, 220VAC for desktop
Dimensions & weight [Panel mounting] Approx. 164(W) x 164(H) x 261(D) Approx. 5.5kg
[Desktop] Approx. 164(W) x 198(H) x 263(D) Approx. 6.5kg

Detectable Gases & Detection Range (For Environment / For Scrubber)
Detectable gas TLV Detection range Resolution 1st Alarm 2nd Alarm Tape No.
Ammonia NH3 25ppm 0.5~4ppm 0.1ppm 1ppm 2ppm FC-010
Arsine AsH3 50ppb 0~150ppb 1ppb 50ppb 100ppb FCL-001
Chlorine Cl2 0.5ppm * 0~0.8ppm 0.01ppm 0.25ppm 0.5ppm FCL-105
0~1.5ppm
Diborane B2H6 100ppb 0~300ppb 5ppb 50ppb 100ppb FCL-002
Hydrogen chlorine HCl 5ppm 0.25~1ppm 0.025ppm 0.5ppm 0.75ppm FC-004
1.5~8ppm 0.1ppm 2.5ppm 5ppm FC-005
Hydrogen fluoride HF 3ppm 0~9ppmb 0.1ppm 1.5ppm 3ppm FC-006
Hydrogen sulfide H2S 10ppm 0~100pp 1ppb 17ppb 34ppb FCL-001
0~10ppm 0.05ppm 1ppm 2ppm
Phosphine PH3 300ppb * 0~500ppb 5ppb 150ppb 300ppb FCL-001
0~900pb
Silane SiH4 5ppm * 0~8ppm 0.1ppm 2.5ppm 5ppm FCL-002
0~15ppm

Datasheets & User Manuals