1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments FP-270 Paper Tape Machine - FP-270

Item #:
FP-270
Brand:
RKI Instruments
$6,300.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments FP-270 Paper Tape Machine - FP-270

RKI Instruments FP-270 Paper Tape Machine - FP-270

$6,300.00

Discontinued


FP-270 Paper Tape Machine by RKI Instruments

The model FP-270 series are highly sensitive toxic gas monitors using a gas detection cassette tape which is almost free of interference from other gases. As the detection tape responds by a chemical reactionwith the gas being measured, there is no interference from hydrogen or organic gases. Its best applicaton then is in monitoring of the target gas at the outletof an absorption scrubber, as well as in monitoring of the work environment for personnel safety.

Octafluorocyclopentene(C5F8) and Perfluorobutadiene(C4F6) can be detected with built in spacial pyrolyzer.

Features

  • Interference-free detection (PPB or PPM digital display)
  • Detection of low gas concentration (TLV level)
  • Easy to replace cassette tape (cassette remainder display included)
  • Provision for connection to personal computer (RS-232C interface:Optional)
  • Easy to check the detection function and alarm operation
  • Desktop size promotes easy transportability
  • Ideal for detection of C5F8, C4F6, THF(C4H8O) with built-in special pyrolyzer

*Please note we can only ship RKI products to customers within the United States

FP-270 Specifications:
Model name FP-270 FP-270AGZ FP-270AGZS
Detection principle Photoelectric photometry method Special pyrolyzer + photoelectric photometry method
Detection tape Cassette tape style
Measuring gas and range Refer to "Detectable gases and detection range table"
Sample flowrate Approx 1.5L/min Approx 1.0L/min
Operating time for cassette tape 1 month (under gas free condition), with tape remainder display and caution display for tape end.
Alarm operation Alarm value Depending upon the measuring gas
Indication Lamp (Warning : Yellow, Alarm : Red) and buzzer
Output Latching alarm contact
Non-energized contact
Non-voltage C contact, 125VAC, 0.5A : Load resistance
Alarm accuracy Within ±20% of alarm setting value at constant condition Within ±30%+1 digit of alarm setting value at constant condition
Initial clear Approx. 25 seconds after turning on the power
Self-diagnosis Contents * Sensor failure, * Flow failure, * Tape cut, * System trouble, * Tape cassette replacement, * Lever set failure
Display * LCD message, * Lamp, * Buzzer
Output * Non-latching contact
* Non-energized contact
* Non-voltage C contact, 125VAC, 0.5A : Load resistance
Output signal * 4-20mA : Not isolated, Max. load resistance : 300 Ω 0-1V : Not isolated, * RS-232C interface (option)
Operating temperature & humidity 5 ~ 35° C; 30 ~ 90%RH ( Non-Condensing) 10 ~ 35°C; 30 ~ 60% RH (Non-condensing)
Gas inlet Outer diameter : 6mmØ, with fitting
Power source 100VAC, 50/60Hz (40VA) 100VAC, 50/60Hz (80VA)
Outer dimensions Approx. 300 (W) x 200 (H) x 370 (D) mm
Weight Approx 12kg Approx 13.5kg
Standard accessories Gas detection cassette tape, Check sheet, Dust filter, Fuse

Datasheets & User Manuals