1-866-4 JJSTECH(1-866-455-7832)

Extech PRC30 Multifunction Process Calibrator with NIST

Item #:
EXT-PRC30-NIST
Brand:
Extech
Extech PRC30 Multifunction Process Calibrator with NIST
$809.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech PRC30 Multifunction Process Calibrator with NIST

Extech PRC30 Multifunction Process Calibrator with NIST

$809.00

Discontinued


PRC30 Multifunction Process Calibrator with NIST by Extech

Precision source and measure for thermocouples (8-Types), mA, mV, and V devices

Features

  • Palm-sized double molded housing and large dot-matrix backlit LCD
  • Measures DC process signals
  • High accuracy calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, controllers or recorders
  • Up to five user adjustable calibration presets
  • Displays output in terms of millivolts or temperature based on thermocouple tables
  • 24V Loop Power
  • Zero adjustment, auto zero when power on and change mode
  • Standard banana I/O ports and mini thermocouple inputs
  • Large battery bank for extended work cycle
  • External power adapter for continuous work cycle

Applications

  • Lab and Field Calibration and Verifi cation Operations of Sensors, Thermocouple Probes, Controllers, Panel meters & Testing tools.
  • Temperature Control Process Troubleshooting
  • Process devices calibration and simulation: Transducers, Transmitters, Indicators, Controllers, and Recorders
  • Field test and service
  • Bench research and development

Includes

  • Test leads
  • Alligator clips
  • Thermocouple calibration cable with subminiature connector
  • Universal calibration cable with subminiature terminal
  • 100V-240V AC Universal Adaptor with 4 plugs
  • Six 1.5V AA batteries
  • Hard carrying case
General Specifications
Display Dot matrix LCD
Cold junction compensation 0.03°C per °C (0.02°F per °F)
Thermocouple Standard and Scale NIST 175, ITS-90
Current output capability 24mADC at 1000 ohms
Voltage input impedance 10kohms minimum
Meter Power 6 AA batteries or AC adaptor
Auto Power OFF Meter automatically powers off after 10 minutes of inactivity
Operating Temperature 5ºC to 40ºC (41ºF to 104ºF)
Storage Temperature -20 ºC to 60 ºC (- 4 ºF to 140 ºF)
Operating Humidity Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF)
Storage Humidity <80%
Operating Altitude 7000ft (2000meters) maximum
Dimensions 159 x 80 x 44 mm (6.3 x 3.2 x 1.7")
Weight 225g (8 oz.) without batteries

Range Specifications
T/C Source and Measure Ranges
Resolution
Accuracy (% of reading)
Type J
-58 to 1832°F (-50 to 1000°C)
0.1° (measure)
1° (source)
± (0.05% + 1°C /1.8°F)
Type K
-58 to 2498°F (-50 to 1370°C)
Type T
-184 to 752°F (-120 to 400°C)
Type E
-58 to 1382°F (-50 to 750°C)
Type C
32 to 3182°F (0 to 1750°C)
Type R
32 to 3182°F (0 to 1750°C)
Type S
32 to 3182°F (0 to 1750°C)
Type N
-58 to 2372°F (-50 to 1300°C)
mV
Measure: -10mV to 60mV
Source: -5mV to 55mV
0.01mV
± (0.01% + 1digit)

Mode
Function
Range (Resolution)
Accuracy (% of reading)
DC Measure
Current
0 to 50mA (0.01mA)
± (0.01% + 1 digit)
Percent (%)
-25% to +230% (0.1%)
Voltage (autoranging)
0 to 2000mV (1mV)
2 to 20V (0.01V)
DC Source
Current
0 to 24mA (0.01mA)
Percent (%)
-25% to +125% (0.1%)
Voltage
0 to 1999mV (1mV)
0 to 20V (0.01V)
Loop Power
Current
24 to 30VDC, <50mA

Datasheets & User Manuals

Questions & Answers