- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech EX505 11 Function Heavy Duty True RMS Industrial MultiMeter
Item #:
EXT-EX505
Brand:
Extech
Share this product:
EX505 11 Function Heavy Duty True RMS Industrial MultiMeter by Extech
Features
- 1000V input protection on all functions
- Dual sensitivity frequency functions
- Large backlit LCD
- Diode open circuit voltage of 2.8V DC
- Auto power off with disable feature
- Complete with double molded test leads, magnetic hanging strap, Type K bead wire temperature probe (EX505, EX520 and EX530), carrying case, and one 9V battery
- 4,000 count
- 0.5% accuracy
- Data Hold and Relative
- 10A max current
Enclosure | Double molded, Waterproof (IP67) |
Shock (Drop Test) | 2 meters (6.5 feet) |
Diode Test | Test current of 0.3mA typical, open circuit voltage 1.5V DC typical |
Continuity Check | Audible signal will sound if the resistance is less than 100 Ω (approx.), test current <0.35mA |
Temperature Sensor | Requires type K thermocouple |
Input Impedance | 7.8MΩ |
AC Response | True rms |
ACV Bandwidth | 40Hz to 400Hz |
Crest Factor | ≤3 at full scale up to 500V, decreasing linearly to ≤1.5 at 1000V |
Display | 4,000 count backlit liquid crystal |
Overrange indication | "OL" is displayed |
Auto Power Off | 30 minutes (approximately) |
Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
Measurement Rate | 2 times per second, nominal |
Low Battery Indication | Battery symbol is displayed if battery voltage drops below operating voltage |
Battery | One 9 volt (NEDA 1604) battery |
Fuses | mA, µA ranges; 0.5A/1000V ceramic fast blow A range; 10A/1000V ceramic fast blow |
Operating Temperature | 5°C to 40°C (41°F to 104°F) |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Operating Humidity | Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F) |
Storage Humidity | <80% |
Operating Altitude | 2000 meters (7000 ft) maximum |
Weight | 342 g (0.753 lb) (includes holster) |
Size | 182 x 82 x 55mm (7.2" x 3.2" x 2.2") |
Safety | This meter is intended for origin of installation use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to Category IV 600V and Category III 1000V; Pollution Degree 2. The meter also meets UL 61010-1, 2nd Edition (2004), CAN/CSA C22.2 No. 61010-1 2nd Edition (2004), and UL 61010B-2-031, 1st Edition (2003) |
Approvals | UL CE |
UL Listed | The UL mark does not indicate that this product has been evaluated for the accuracy of its readings. |
Function |
Range |
Resolution |
Accuracy |
DC Voltage |
400mV |
0.1mV |
±(0.5% reading + 2 digits) |
4V |
0.001V |
±(1.2% reading + 2 digits) |
|
40V |
0.01V |
||
400V |
0.1V |
||
1000V |
1V |
±(1.5% reading + 10 digits) |
|
AC Voltage |
400mV |
0.1mV |
±(2.0% reading + 10 digits) |
4V |
0.001V |
±(2.0% reading + 5 digits) |
|
40V |
0.01V |
||
400V |
0.1V |
||
1000V |
1V |
±(2.5% reading + 5 digits) |
|
DC Current |
400μA |
0.1μA |
±(1.0% reading + 3 digits) |
4000μA |
1μA |
±(1.5% reading + 3 digits) |
|
40mA |
0.01mA |
||
400mA |
0.1mA |
||
10A |
0.01A |
±(2.5% reading + 5 digits) |
|
AC Current |
400μA |
0.1μA |
±(2.5% reading + 10 digits) |
000μA |
1μA |
±(2.5% reading + 5 digits) |
|
40mA |
0.01mA |
||
400mA |
0.1mA |
||
10A |
0.01A |
±(3.0% reading + 7 digits) |
|
Resistance |
400Ω |
0.1Ω |
±(1.2% reading + 4 digits) |
4kΩ |
0.001kΩ |
±(1.0% reading + 2 digits) |
|
40kΩ |
0.01kΩ |
±(1.2% reading + 2 digits) |
|
400kΩ |
0.1kΩ |
||
4MΩ |
0.001MΩ |
||
40MΩ |
0.01MΩ |
±(2.0% reading + 3 digits) |
|
Capacitance |
4nF |
0.001nF |
±(5.0% reading + 0.5nF) |
40nF |
0.01nF |
±(5.0% reading + 7 digits) |
|
400nF |
0.1nF |
±(3.0% reading + 5 digits) |
|
4μF |
0.001μF |
||
40μF |
0.01μF |
||
100μF |
0.1μF |
±(5% reading + 5 digits) |
|
Frequency |
5.999Hz |
0.001Hz |
±(1.5% reading + 1 digits) |
59.99Hz |
0.01Hz |
||
599.9Hz |
0.1Hz |
±(1.2% reading + 3 digits) |
|
5.999kHz |
0.001kHz |
||
59.99kHz |
0.01kHz |
||
599.9kHz |
0.1kHz |
||
5.999MHz |
0.001MHz |
±(1.5% reading + 4 digits) |
|
9.999mHz |
0.001MHz |
||
Sensitivity: 0.5V rms <500kHz; 3V rms >500kHz |
|||
Duty Cycle |
0.1 to 99.9% |
0.1% |
±(1.2% reading + 2 digits) |
Pulse width: 100µs to 100ms, Frequency: 5Hz to 150kHz |
|||
Temp (type-K) |
-4 to 1382°F |
0.1°<400° 1° ≥ 400° |
±(3.0% reading + 5°C /9°F) (probe accuracy not included) |
-20 to 750°C |