Discontinued


EX320 8 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST by Extech

Features

  • 0.5% basic accuracy
  • Built-in non-contact AC Voltage Detector with red LED indicator and audible beeper
  • Large 1" digits make it easy to read
  • Low battery indicator
  • Complete with stand, test leads, protective holster, batteries, general purpose bead wire temperature probe (Model EX330)
  • Autoranging
  • Max Hold: captures highest reading
  • Data Hold: freezes the display
  • Auto Power Off: conserves
General Specifications
Diode Test Test current: 0.3mA max., Open circuit voltage: 1.5V DC typ.
Continuity Check Audible signal will sound if the resistance is less than 100 Ω
Input Impedance 10MΩ (VDC & VAC)
AC Bandwidth 50 / 60Hz
Display 2000 count (0 to 1999 digits) backlit LCD
Overrange indication For all functions "OL" is displayed
Auto Power Off After 15 minutes (approximately) of inactivity
Polarity No indication for positive; Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication Battery symbol is displayed if battery voltage is critically low
Battery Two (2) 1.5V 'AAA' batteries
Fuses 200mA/250V fast blow; (5x20mm); 10A/250V fast blow (5x20mm)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity <70% RH
Storage Humidity <80% RH
Operating Altitude 2000 meters (7000ft) maximum
Weight 260g (9.17 oz) (includes holster)
Size 147 x 76 x 42mm (5.8" x 2.9" x 1.6") (includes holster)
Approvals CE
Safety This meter is intended for indoor use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT II 1000V & CAT III 600V; Pollution Degree 2. The meter also meets UL 61010-1, Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second Edition (2004), and UL 61010B-2-031, First Edition (2003)

Range Specifications
Function
Range
Resolution
Accuracy
Non-contact AC Voltage detector
100 to 600VAC
Resolution & accuracy do not apply since the meter does not display the voltage in this mode. The lamp at the top of the meter’s display flashes when voltage is sensed and an audible warning will sound
DC Voltage (V DC)
200mV
0.1mV
±(0.5% reading + 2 digits)
2V
0.001V
±(1.0% reading + 2 digits)
20V
0.01V
200V
0.1V
600V
1V
±(1.5% reading + 2 digits)
AC Voltage (V AC) (50 / 60Hz)
200mV
0.1mV
±(1.0% reading + 30 digits)
2V
0.001mV
±(1.5% reading + 3 digits)
20V
0.01V
200V
0.1V
600V
1V
±(2.0% reading + 4 digits)
DC Current (A DC)
200μA
0.1μA
±(1.0% reading + 3 digits)
2000μA
1μA
±(1.5% reading + 3 digits)
20mA
0.01mA
200mA
0.1mA
10A
0.01A
±(2.5% reading + 5 digits)
AC Current (A AC) (50 / 60Hz)
200μA
0.1μA
±(1.5% reading + 5 digits)
2000μA
1μA
±(1.8% reading + 5 digits)
20mA
0.01mA
200mA
0.1mA
10A
0.01A
±(3.0% reading + 7 digits)
Resistance
200Ω
0.1Ω
±(1.2% reading + 4 digits)
2kΩ
±(1.2% reading + 2 digits)
20kΩ
0.01kΩ
200kΩ
0.1kΩ
2MΩ
0.001MΩ
20MΩ
0.01MΩ
±(2.0% reading + 3 digits)