EX210T TrueRMS Digital Multimeter with IR and NIST by Extech

Both models are autoranging True RMS meters providing a more accurate reading when measuring distorted waveforms. EX210T with built-in IR Thermometer allows for quick noncontact Temperature measurements.

Features

  • True RMS for better accuracy when measuring distorted waveforms
  • Patented built-in IR Thermometer with laser pointer for locating hot spots with 4:1 Distance to Target Ratio (EX210T model only)
  • 2000 count large backlit dual LCD with easy-to read digits
  • Low current capability with resolution to 0.1μA
  • Max Hold
  • Input fuse protection
  • Auto power off and Data Hold
  • Complete with test leads and 9V battery
General Specifications
Enclosure Double molded
Diode Test Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Continuity Threshold 20 to 50Ω, test current <1.5mA
Input Impedance 10MΩ VDC/VAC
AC Response True rms
ACV Bandwidth 40Hz to 1000Hz
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 4:1
Laser pointer Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Display 2,000 count backlit liquid crystal display
Over-range indication "OL" is displayed
Auto Power Off 15 minutes (approximately)
Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Battery One 9 volt (NEDA 1604) battery
Fuses mA, µA ranges; 200mA 250V ceramic fast blow
A range; 10A 600V ceramic fast blow
Operating Temperature -10°C to 40°C (14°F to 122°F)
Storage Temperature -10°C to 60°C (14°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000 meters (7000 ft) maximum
Weight 260g (9.17oz)
Size 147 x 76 x 42mm (5.8 x 2.9 x 1.6")
Safety This meter is intended for origin of installation use and protected, against the users, by double insulation per IEC/EN 61010-1:2001 and IEC/EN 61010-031:2002 to Category III 600V; Pollution Degree 2.
Approvals CE

Range Specifications
Function
Range
Resolution
Accuracy
DC Voltage
200 mV
0.1 mV
±(0.8% reading + 6 digits)
2V
0.001V
±(0.5% reading + 2 digits)
20V
0.01V
200V
0.1V
±(0.8% reading + 2 digits)
600V
1V
AC Voltage (50/60Hz) True RMS
200 mV
0.1 mV
±(1.5% reading + 6 digits)
2V
0.001V
20V
0.01V
200V
0.1V
600V
1V
All AC voltage ranges are specified from 5% of range to 100% of range
DC Current
200 µA
0.1 µA
±(1.5% reading + 5 digits)
2000 µA
1 µA
20 mA
0.01 mA
200 mA
0.1 mA
2.000
0.001 A
±(2.5% reading + 5 digits)
10 A
0.01 A
Note:10A for 30 sec max
AC Current (50/60Hz) True RMS
200 µA
0.1 µA
±(1.5% reading + 8 digits)
2000 µA
1 µA
20 mA
0.01 mA
200 mA
0.1 mA
2.000
0.001 A
±(3.0% reading + 5 digits)
10 A
0.01 A
Note: 10A for 30 sec max
Resistance
200 Ω
0.1 Ω
±(0.8% reading + 5 digits)
2 kΩ
0.001 kΩ
±(0.8% reading + 2 digits)
20 kΩ
0.01 kΩ
200 kΩ
0.1 kΩ
2 MΩ
0.001 MΩ
±(2.5% reading + 8 digits)
20 MΩ
0.01 MΩ
Temperature IR
20 to 0°C
0.1°C/°F
±4°C
0 to 93°C
±(2.0%rdg or 2°C)
93 to 230°C
±(3.0%rdg or 3°C)
-5 to 32°F
± 8°F
32 to 200°F
±(2.0%rdg or 4°F)
200 to 446°F
±(3.0%rdg or 6°F)