1-866-4 JJSTECH(1-866-455-7832)

Extech AN340 CMM/CFM Anemometer/Psychrometer Datalogger with NIST

Item #:
EXT-AN340-NIST
Brand:
Extech
Extech AN340 CMM/CFM Anemometer/Psychrometer Datalogger with NIST
$703.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech AN340 CMM/CFM Anemometer/Psychrometer Datalogger with NIST

Extech AN340 CMM/CFM Anemometer/Psychrometer Datalogger with NIST

$703.99

Discontinued


AN340 CMM/CFM Anemometer/Psychrometer Datalogger with NIST by Extech

Telescoping probe with 18mm diameter vane sensor easily fits into air vents and can extend length of probe to 3.3ft (1m) long. Measures Air Velocity/Volume, Temperature, Humidity, Wet Bulb, and Dew Point. User can store up to 12,000 readings for data analysis.

Features

  • Telescoping 0.7" (18mm) diameter vane sensor extends from 1ft (0.3m) up to 3.3ft (1m)
  • Measures Air Velocity, Air Flow, Air Temperature, Humidity, Dew Point and Wet Bulb
  • Manually store/recall up to 99 readings
  • Automatically datalog up to 12000 readings with 12/24 hour time and date stamp
  • Select data sampling rate from 1s to 4hr: 59 min: 59s
  • Min/Max/Avg readings
  • Data hold and Auto power off with disable
  • Built-in PC Interface
  • Complete with external mini vane probe, Windows® compatible software, USB cable, 6 AAA batteries, and hard carrying case

Applications

  • HVAC with small ducts and vents
  • Manufacturing
  • Engineering
  • Appliance Testing
  • Research and Design
General Specifications
Circuit Custom LSI microprocessor
Display Dual function 32.5 (H) x 54 (W) mm (1.3 x 2.1") LCD
Sampling rate 1 reading per second approx.
Air velocity/flow sensor Angled mini‐vane arms with low‐friction ball bearing
Sensors NTC - type precision thermistors
Automatic Power off Auto shut off after 20 minutes to preserve battery life (sleep mode)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to 50°C (-4 to 122°F)
Operating Humidity <80% RH
Storage Humidity <90% RH
Operating Altitude 2000 meters (7000ft) maximum
Battery Power Six (6) 'AAA' 1.5V batteries
Battery Life > 40 hours
Battery consumption 14 mA DC (approx.)
Weight 210g (0.5 lbs.) including batteries
Dimensions Main instrument L x W x H: 169 x 78.3 x 44mm (6.6 x 3.1 x 1.7 ")
Sensor diameter: 18mm (0.7"); Telescoping wand extends 1m (39”)

Range Specifications
Air Velocity
m/s (meters per second) Range: 0.5 - 20 m/s
Resolution: 0.1 m/s
Accuracy: ± (3% rdg + 0.2 m/s)
fpm (feet per minute) Range: 98 - 3937 fpm
Resolution: 1 fpm
Accuracy: ± (3% rdg + 39 fpm)
Relative Humidity
RH Range: 0.1%‐99.9%RH
Resolution: 0.1 RH
Accuracy: ±3%RH (10‐90%RH); ±5%RH (<10% or >90%)
Air Flow
CMM (cubic meters/min) Range: 0 - 99999 m3 /min
Resolution: 0.1 up to 9999.9 then 1.0
Area Range: 0 to 99999cm2
CFM (cubic ft/min) Range: 0 - 99999 ft3 /min
Resolution: 0.1 up to 9999.9 then 1.0
Area Range: 0 to 99999in2
Temperature
°C/°F Air and Wet Bulb Range: -20 to 60°C (-4 to 140°F)
W et Bulb temperature: ‐20 to 70°C (‐4 to 158°F)
Dew Point Range: ‐20 to 60°C (-4 to 140°F)
Resolution: 0.1°C/°F
Accuracy: ±0.6°C (0 to 50°C); ±1.2°C (below 0°C, above 50 °C); ± 1.1°F (32 to 122°F); ± 2.2°F (below 32°F, above122°F)

Datasheets & User Manuals

Questions & Answers