- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech 480836 RF EMF Strength Meter
Item #:
EXT-480836
Brand:
Extech
Share this product:
480836 RF EMF Strength Meter by Extech
Features
- For electromagnetic field strength measurement including mobile phones, cell phones, base stations, and microwave leakage
- Measurement optimized for 900MHz, 1800MHz and 2.7GHz
- Non-directional (isotropic) measurement with three-channel (triaxial) measurement probe
- Max Hold and Average functions
- Manual store/recall up to 99 sets
- Level exceed audible alarm with user selectable threshold
- Complete with 9V battery and carrying case
Applications
- RF electromagnetic wave field strength measurements
- Mobil phone base station antenna radiation power density measurement
- Radiation safety level tests
- Locating RF "Hot Spots" in the workplace or at home
- Microwave oven leakage tests
- RF "Electrosmog" detection
- Wireless network (Wi-Fi) RF detection
Measurement method | Digital, triaxial measurement |
Directional characteristic | Isotropic, triaxial |
Measurement ranges | One continuous range |
Display resolution | 0.1mV/m, 0.1μA/m, 0.1μW/m2 , 0.001μW/cm2 |
Setting time | Typically 1s (0 to 90% of measurement value) |
Display refresh rate | Typically 0.5 seconds |
Display type | 4-digit Liquid-crystal display (LCD) |
Audible alarm | Buzzer |
Units | mV/m, V/m, μA/m, mA/m, μW/m2 , mW/m2 , W/m2 , μW/cm2, mW/cm2 |
Display value | Instantaneous measured value, maximum value, or maximum average value |
Alarm function | Adjustable threshold with ON/OFF. |
Manual data memory and read storage | 99 data sets. |
Dry batteries | 9V NEDA 1604/1604A |
Battery life | > 15 hours |
Auto power off | 15 minutes. |
Operating temperature range | 0°C to +50°C |
Operating humidity range | 25% to 75%RH |
Storage temperature range | -10°C to +60°C |
Storage humidity range | 0% to 80%RH |
Dimensions | Approx. 60(W) x 60(T) x 237(L)mm |
Weight (including battery) | Approx. 200g |
Accessories | Instruction manual, battery, carrying case. |
Electrical Specifications | |
Sensor type | Electrical field (E) |
Frequency ranges | 900MHz, 1800MHz, and 2.7GHz (measurements can be made, for reference purposes only, using the entire range of 50MHz to 3.5GHz) |
Specified measurement range | |
CW signal (f > 900MHz) | 20mV/m to 108.0V/m , 53μA/m to 286.4mA/m, 1μW/m2 to 30.93W/m2 , 0μW/cm2 to 3.093mW/cm2 |
Dynamic range | Typically 75dB |
Absolute error at 1 V/m and 50 MHz | ±1.0dB |
Frequency response | |
Sensor (taking into account typical CAL factors) | ±1.0dB (900MHz, 1800MHz) ±2.4dB (2.7GHz) |
Isotropy deviation | Typically ±1.0dB (f>900MHz) |
Overload limit | 10.61mW/cm2 (200V/m) |
Thermal response (0 to 50C) | ±0.2dB |