- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech 407119 Heavy Duty CFM Hot Wire Thermo-Anemometer with NIST
Item #:
EXT-407119-NIST
Brand:
Extech
Share this product:
407119 Heavy Duty CFM Hot Wire Thermo-Anemometer with NIST by Extech
Features
- Air velocity measurements as low as 40ft/min
- Telescoping probe is ideal for use in ducts and ventilating systems; extends up to 3ft (940mm) long
- Measures air volume in CFM (ft3/min) and CMM (m3/min) plus Temperature simultaneously
- Air Flow displayed in 2 modes as an instantaneous value or up to 20 point average
- Record/Recall MIN and MAX readings
- Super large 1.4" LCD display
- Data Hold plus Auto Power Off
- Built-in RS-232 PC interface with optional Data Acquisition software and cable
- Complete with telescoping probe with 5.5ft (167.6cm) cable, and four AA batteries
Display | Dual function 5-digit LCD |
Measurements | Air Velocity: m/s, km/h, ft/min, knots, mph; Air Flow: CMM (m3/min) and CFM (ft3/min); Temperature: °C and °F |
Data Hold | Freezes displayed reading |
Sampling rate | Display update rate:1 second (approx.) |
Sensors | Air velocity and temperature sensors: Thermistor type |
MAX/MIN Memory | Record and view Maximum and Minimum readings |
Average feature | Averages up to 20 readings |
Auto Power OFF | Automatic shut off after 15 minutes |
Data Output | RS-232 PC serial interface with 16-bit data stream output |
Operating Temp. | 0 to 50°C (32 to 122°F) |
Operating Humidity | Max. 80% Relative Humidity |
Power Supply | Four (4) 'AA' 1.5V batteries or optional AC adaptor |
Power Current | 70mA DC (approx.) |
Weight (meter only) | 521g (1.15 lbs.) with batteries installed |
Dimensions | Main instrument: 200.0 x 76.2 x 36.8mm (7.9 x 3.0 x 1.5") Telescoping Sensor: 12.7mm (0.5") diameter head Min length of sensor: 260mm (8"); Max. length: 0.94m (37") with 1.7m (5.5') cable |
Air velocity | |
m/s (meters/second) | Range: 0.2 – 17.0 m/s Resolution: 0.1 Accuracy (of rdg): ±(5% + 5 digits) |
Km/h (kilometers/hour) | Range: 0.7 – 61.2 km/h Resolution: 0.1 Accuracy (of rdg): ±(5% + 20 digits) |
ft/min (feet per minute) | Range: 40 – 3346 ft/min Resolution: 1 Accuracy (of rdg): ±(5% + 100 digits) |
mph (miles per hour) | Range: 0.5 – 38.0 mph Resolution: 0.1 Accuracy (of rdg): ±(5% + 10 digits) |
knots (nautical miles per hour ) | Range: 0.4 to 33.0 knots Resolution: 0.1 Accuracy (of rdg): ±(5% + 10 digits) |
Air Flow Measurements | |
CMM (cubic meters per minute) | Range: 0 – 36,000 m3/min Resolution: 0.001 to 1 Area Range: 0.001 to 30.0 m2 |
CFM (cubic feet per minute) | Range: 0 – 1,271,200 ft3/min Resolution: 0.01 to 100 Area Range: 0.01 to 322.91 ft2 |
Air Temperature | Range: 0 to 50°C
(32 to 122°F) Resolution: 0.1°C/F Accuracy: ±0.8°C (1.5°F) |