1-866-4 JJSTECH(1-866-455-7832)

E Instruments E500 Residential Combustion Efficiency Analyzer with O2, CO, CO2, NO, NOx, Heat Losses, Draft, Pressure, Excess Air, Temperature, Calculations for High Efficiency & Condensing Systems - Included Wireless Bluetooth Printer - E500-3P

Item #:
E500-3P
Brand:
E Instruments
E Instruments E500 Residential Combustion Efficiency Analyzer with O2, CO, CO2, NO, NOx, Heat Losses, Draft, Pressure, Excess Air, Temperature, Calculations for High Efficiency & Condensing Systems - Included Wireless Bluetooth Printer - E500-3P
$2,179.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
E Instruments E500 Residential Combustion Efficiency Analyzer with O2, CO, CO2, NO, NOx, Heat Losses, Draft, Pressure, Excess Air, Temperature, Calculations for High Efficiency & Condensing Systems - Included Wireless Bluetooth Printer - E500-3P

E Instruments E500 Residential Combustion Efficiency Analyzer with O2, CO, CO2, NO, NOx, Heat Losses, Draft, Pressure, Excess Air, Temperature, Calculations...

$2,179.00

E500-3P E500 Residential Combustion Efficiency Analyzer with O2, CO, CO2, NO, NOx, Heat Losses, Draft, Pressure, Excess Air, Temperature, Calculations for High Efficiency & Condensing Systems - Included Wireless Bluetooth Printer by E Instruments

Accurate / Reliable / Economical / Easy

  • 6 Tools-In-One
  • CO Sensor with NOx Filter
  • Flue and Ambient Temp
  • Ambient CO Monitor
  • Built-In Manometer
  • Combustion Efficiency
  • Draft & Pressure
  • Smartphone Apps

  • O2, CO, CO2, NO, NOx
  • Economical & Easy to Use
  • Long Lasting Rechargeable Battery & AC Charger
  • iOS and Android Mobile Applications
  • True High-Efficiency Calculations for All Condensing Systems
  • Optional Wireless Bluetooth® Printer

Standard Probe Details:

  • 12" (300mm) probe
  • 1470 °F (800 °C) max
  • 5' (1.5m) Dual Hose

All E500 Kits Include:

  • O2, CO, CO2
  • Upgradeable to NO/NOx
  • Combustion Efficiency, Losses, Excess Air
  • CO Air Free
  • Draft Measurement
  • Pressure Measurment
  • Temperature Measurements
  • Long Lasting Rechargeable Battery & AC Charger
  • Gas Sampling Probe & Hose
  • Water Trap with Filter Cartridge
  • Magnetic Rubber Holster
  • Operating Manual
  • Calibration Certificate
  • IR Interface
  • ABS Carrying Case
  • Outdoor Air Calculations for Condensing Systems
Parameter Sensor Range Resolution Accuracy
O2 Electrochemical 0 - 25 % 0.1 % ±0.2 % vol
CO H2 compensated w/ built-in NOx filter Electrochemical 0 - 4000 ppm 1 ppm ±10 ppm <400 ppm
±5 % rdg up to 2000 ppm
±10 % rdg for >2000 ppm
CO2 Calculated 0 - 99.9 % 0.1 % -
NO Electrochemical 0 - 2000 ppm 1 ppm ±5 ppm <100 ppm
±5 % rdg up to 1000 ppm
±10 % rdg for >5000 ppm
NOx Calculated 0 - 2000 ppm 1 ppm -
Tair Tc K -4 to 248 °F
-20 to 120 °C
0.1 °F
0.1 °C
±1 °F
±1 °C
Tgas Tc K -4 to 1472 °F
-20 to 800 °C
0.1 °F
0.1 °C
±2 °F
±2 °C
Differential temperature Calculated -4 to 1472 °F
-20 to 800 °C
0.1 °F
0.1 °C
-
Pressure/Draft Semiconductor -4 to 40 inH2 O
-10 to 100 mbar
0.001 inH2 O 0.01 mbar ±1 % rdg.
Excess air Calculated 0 - 850 % 1 % -
Efficiency Calculated 0 - 100 % 0.1 % -
Warranty 2 years: analyzer + sensors