- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
E Instruments E1100-1 Industrial Combustion Analyzer with O2 (0-25%) and CO (0-8000ppm) Field Replaceable Sensors
Item #:
E1100-1
Brand:
E Instruments
Share this product:
E Instruments E1100 Industrial Combustion Analyzer
For combustible applications, E Instruments International presents the E1100 Industrial Combustion Analyzer. The handheld device is essential for working with potentially hazardous equipment such as boilers, furnaces, engines, kilns, heaters, and other combustible instruments. Its rubber casing is also magnetic allowing for a convenient hands-free operation. With its built in printer, user can receive instant read outs of air quality status and more. The analyzer has a variety of sensor options to meet most needs. It was carefully crafted to meet customer demands and statutory requirements.
User Friendly Features
One of the more user friendly aspects of the Industrial Combustion Analyzer is the availability of pre-calibrated sensors. The analyzer is designed to allow maximum efficiency in the field, and the pre-calibrated sensors can be easily replaced while on the job site. Another user friendly feature is the built in internal non-thermal impact printer. Users will not need connectivity, extra parts, or external communication when printing on the job site. The printer can print up to 40 analysis reports with the batteries fully charged. The analyzer also has a large backlit blue LCD display screen with a zoom feature. This feature is intuitive and easy to read. Additionally, the device has unbreakable metal probe connectors which help to improve the operability and life of the device. More user friendly features include
- Magnetic rubber boot
- CO sensor with NOx filter
- Draft and differential pressure meter
- Rechargeable Li-Ion battery
- PC software with USB cable and BlueTooth Communications
- Immediate response times for environmental quality readings
Inside the unit, the device is divided into seven compartments that allow for each component to be safely housed inside the durable plastic casing. The keypad is an incredibly intuitive feature that provides complete control over the unit by the user.
When purchased, the unit comes with the software package, a rechargeable battery, an AC plug, a dual hose, a probe, a vinyl case, a calibration certificate, an operating manual, a water trap, a paper roll, 600 test memory, and a built in printer.
E Instruments International
E Instruments International manufactures a variety of analyzers to measure and record air quality. Their product offerings range from combustible gases to indoor air quality analyzers and are specifically developed for the industrial, power, institutional, process, food, and HVAC industries. E Instruments is well known for its incredible dedication to customer service and its consistent output of customer oriented industrial instruments.
Parameter |
Sensor |
Range |
Resolution |
Accuracy |
O2 | Electrochemical | 0 - 25% | 0.1% | ±0.2% vol |
CO H2 Compensated w/ Built-in NO Filter | Electrochemical | 0 - 8000 ppm | 1 ppm | ±20 ppm <400ppm ±5% rdg up to 2000 ppm ±10% rdg for >2000 ppm |
CO2 | Calculated | 0 - 99.9% | 0.1% | |
Tair | Pt100 | -10 to 212°F | 0.1°F | ± 1°F± 2°F |
Tgas | Tc K | -10 to 1830°F | 0.1°F | ± 2°F |
Differential Temp. | Calculated | -10 to 2280°F | 0.1°F | |
Pressure/Draft | Semiconductor | + 0 - 80 inH O | 0.001 inH O | ±0.008 inH O for ±0.16 2 inH O ± 5% meas. val. 2 elsewhere |
Excess Air | Calculated | 0 - 850% | 1 % | |
Efficiency | Calculated | 0 - 100% | 0.1% (also for condensing boilers with automatic detection) |