- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Draeger X-am 5600 Multi-Gas Detector, IR EX O3, O2, CO-LC, Rechargeable Kit - VN00128
Item #:
DR-VN00128
Brand:
Draeger
Share this product:
VN00128 X-am 5600 Multi-Gas Detector, IR EX O3, O2, CO-LC, Rechargeable Kit by Draeger
Featuring an ergonomic design and innovative infrared sensor technology, the Draeger X-am® 5600 is the smallest gas detection instrument for the measurement of up to 6 gases. Ideal for personal monitoring applications, this robust and water-tight detector provides accurate, reliable measurements of explosive, combustible and toxic gases and vapors as well as oxygen.
Small yet robust
Small, light and easy to use—the robust and water-tight gas detector X-am 5600 is designed for single-handed operation in tough industrial environments. Water- and dustproof according to IP67 and with an integrated rubber boot, the device provides optimal functionality even under harsh conditions.
Durable infrared technology
Thanks to the high stability and a resistance to contamination, Draeger infrared sensors can generally be used for up to eight years. This advanced technology reduces the cost of ownership considerably because less replacement sensors are needed. In addition, a sensor calibration is only necessary every 12 months which reduces maintenance costs.
Single or dual sensor—accurate measurement results
The infrared sensor IR Ex allows the measurement of explosive, combustible hydrocarbons in the range of the lower explosive limit. The infrared sensor IR CO2, with a measurement resolution of 0.01 Vol.-%, provides safe and exact measurements as well as a warning against toxic concentrations of carbon dioxide in the ambient air. For those applications where the reliable measurement of explosive substances and CO2 is specifically needed, the advantages of both can be achieved by a dual sensor (Dual IR CO2/Ex).
Pump or diffusion mode – suitable for your respective application
The X-zone 5800 offers two options for sampling gas: remote pump from 30 m (98 ft) for Zone 0 or diffusion. The pump or diffusion cover plate can be changed without tools.
Also in combination with Hydrogen
Besides hydrocarbons, hydrogen can also be an explosive gas. Because sensors based on infrared technology do not warn against hydrogen explosion dangers, the gas detector X-am 5600 combines two sensor signals (Infrared Ex and electrochemical H2) for reliable hydrogen detection. The X-am 5600 provides the advantages of poison-free technology to be used in areas where, until now, only catalytic Ex sensors have been used.
Various monitoring possibilities
Thanks to the combination of innovative infrared technology and the latest electrochemical Draeger XXS miniature sensors, this 1-to-6 gas detector reliably detects explosive, combustible and harmful concentrations of O2, Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2, O3, Amine, Odorant, COCl2 and organic vapors. With the PC software Draeger CC-Vision, the sensors can easily be exchanged, calibrated or converted to meet the needs of different applications.
Flexible use
An optional external pump which can be operated with hoses up to 45 m / 147 ft in length is the perfect solution for pre-entry measurements in tanks or pipelines. To monitor entire areas, the gas detector X-am 5600 can be used in combination with the innovative air monitor Draeger X-zone 5500.
Suitable for Ex-Zone 0
The small and reliable gas detector is suitable for use in areas classified as zone 0, which are areas where explosive atmospheres are always to be expected.
Area monitoring
In combination with the Draeger X-zone 5500 the gas detector can be used for various area monitoring applications. Up to 25 Draeger X-zone 5500 units can be automatically interconnected to form a wireless fenceline. This interconnection of the area monitoring devices allows for the fast securing of larger areas, e.g. pipelines or industrial tanks—even within the scope of industrial shutdowns.
Dimensions (W x H x D) | 1.85 x 5.12 x 1.73 inches; 47 x 130 x 44 mm |
Weight | 8.8 oz.; 250 g |
Ambient conditions | Temperature: -4 to +122 °F; -20 to +50 °C Pressure: 700 to 1,300 mbar; 20.7 to 38.4 inch Hg Humidity: 10 to 95% RH |
Alarms | Visual: 360° Audible: Multi-tone >90 dB at 30 cm; 1 ft. |
Ingress Protection | IP67 |
Operating time | ~10 h or rather ~12 h |
Charging time | < 4 hours |
Data logger | Can be read out via Infrared >1,000 hours with 6 gases and a recording interval of 1 value per minute |
Pump operation | Maximum hose length 45 m; 147 ft. |
Approvals | ATEX: I M1 Ex ia I Ma; II 1G Ex ia IIC T4/T3 Ga IEC: Ex ia l Ma; Ex ia llC T4/T3 Ga for MQG 01 MED: Marine Equipment Directive (0736-YY) CSA: Class I, Div. I, Groups A, B, C, D TC T4/T3; Class I, Zone 0, A/Ex ia IIC T4/T3 /Ga |