- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Draeger Pac 6000 O2 - 8326322
Item #:
DR-8326322
Brand:
Draeger
Share this product:
8326322 Pac 6000 O2 by Draeger
The Draeger Pac® 6000 disposable personal gas detector measures CO, H2S, SO2 or O2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years with virtually no maintenance required.
Strong performance for maximum safety
You can rely on the Draeger Pac 6000: The personal single gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulfide, sulfur dioxide or oxygen with precision and reliability. Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6000 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
Easy handling thanks to clear user guidance
The D-Light indicates whether the functionality of the device has been tested and that it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Draeger Pac 6000 features a clearly visible color coding, thereby minimizing the chance of mistakes.
Robust design – even for the toughest conditions
The Pac 6000 can easily handle even extreme conditions: depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.
A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemicalresistant housing meets the requirements specified in the IP68 standard rating.
User-friendly display with all important information
The large display clearly indicates the respective gas concentration. Other important information, such as remaining operating time and battery capacity, is also displayed. The bright backlighting ensures clear reading of all values in the dark.
360° alarm with various functions
If the Draeger Pac 6000 measures hazardous gas concentrations, it sets off an audible, visual, and noticeable vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic alarm reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time, even if acknowledged.
The Pac 6000 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold setting. This provides an additional level of safety as a pre-alarm, in addition to the main alarm, can be set for both oxygen enriched and oxygen deficient atmospheres.
Data logger and event logger for analyses and reports
The Pac 6000 logs concentrations and events along with date and time. The data can be downloaded to a PC via an interface and processed further there.
Economical operational costs
All of the versions of the Pac 6000 are equipped with extremely durable Draeger Sensors and a powerful battery. Neither the sensor nor the battery need to be changed for the entire two-year maintenance-free service life of the H2S, SO2 and CO versions. The service life of the Draeger Pac 6000 starts when it is first activated. The device automatically switches off after two years.
The Pac 6000 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled you can quickly and easily replace it yourself. The device is then ready to use again in no time.
Fast function test saves time and money
Function tests and calibrations can be carried out efficiently using the Draeger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to short test duration and extremely low test gas consumption. The Draeger Pac 6000 is simply placed in the bump test station and automatically selects the correct setting.
Dimensions (without clip) (W x H x D) | 2.5 x 3.3 x 0.8 in, 64 x 84 x 20 mm |
Weight | Approx. 3.7 ounces, 106 g (4.0 ounces, 113 g with clip) |
Device service life | 2 years from first activation |
Battery service life | 2 years (O2 min. 12 months) |
Degree of protection | IP68 |
Air pressure | 700 to 1,300 hPa |
Air humidity | 10 to 90% relative humidity, non-condensing |
Temperature | -22 °F to 131 °F, -30 °C to +55 °C (briefly down to -40 °F/ -40 °C for 1 hr, depending on sensor) |
Approvals | cCSAus, IECEx, ATEX, CE |