- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Draeger X-dock 5300 (X-am 125) - 8321880
Item #:
DR-8321880
Brand:
Draeger
Share this product:
8321880 X-dock 5300 (X-am 125) by Draeger
Automatic bump tests, calibration, reduced test gas consumption, short testing times, and comprehensive documentation come standard in this new device from Draeger, the experts in gas detection.
Work smarter, work safer
The X-dock® engineered advantage all starts with intuitive touchscreen operation at the master controller station where up to three test routines can be configured. Testing is as simple as inserting your Draeger gas detection instrument and closing the lid. The X-dock® immediately detects all sensor combinations and automatically tests and adjusts when all of the required test gases are connected. All generated data is documented in the database.
Comprehensive documentation
All of the relevant data from the test is collected for detailed evaluations providing you with the tools for unparalleled analytics. The report wizard can be used to create customized reports and calibration certificates can be printed right at the stations via PostScript-compatible USB printers. Also documented are items such as instrument operational status and name of tester.
Convenience and control
The X-dock® Manager software produces a detailed evaluation of the data in the calibration system and gas detection instruments and presents the information in various graphics and statistical models—providing you with a comprehensive overview of all results. Multiple X-dock® systems can be connected in a network giving all users access to data in a central database.
Configurations for every need
The Draeger X-dock® on all sitings comes in multiple configurations to allow for flexibility, depending on the type of detection instrumentation being used.
The X-dock® 5300 includes a master controller with a module for a single gas detection instrument in the X-am® or Pac family of products. The X-dock® 6300 and 6600 versions can be configured freely. They consist of a master controller and can be expanded with up to 10 modules for X-am® 1/2/5000 and/or Pac single gas detection instruments. For the X-am 8000 it can be expanded to with up to 5 modules.
Reduced test gas use means reduced costs
With a reduced gas flow (300 mL/min instead of 500 mL/min = 40% decrease) per module, you save money on test gases. Short testing times also reduce the overall maintenance requirements. Draeger's patent pending innovative valve concept only needs one pump, which means less wear on parts for you. The valves automatically switch the test gases and the fresh air source as well.
Time is money. You save both with the X-dock®
Up to 10 modules can be connected to the X-dock®, allowing you to test gas detection instruments simultaneously or independently of each other. The automatic bump test also saves time, because the test only takes 8 to 15 seconds. All Draeger test gas cylinders are already stored in the database—just enter the part number to automatically fill the fields required for the gas configuration, eliminating the need for manual data entry.
Further Benefits
- Touchscreen operation at the master controller station
- Up to three configurable test routines
- Automatic permeability tests
- Automatic tests of all alarm elements (acoustic, visual and vibration alarms)
- Optional charging function for X-am®
- Easy to replace seal cartridge
- 12V operation (e.g., in vehicles) vailable
- Can be subsequently expanded with up to max. 10 modules (X-dock® 6300/6600)
- Sensor performance testing
X-dock® Master Controller | X-dock® Module Pac | X-dock® Module X-am 125 | X-dock® Module X-am 125+ | X-dock® Module X-am® 8000 | X-dock®Module X-am®8000+ | |
Weight | Approx. 3.3 lbs | Approx. 1.98 lbs | Approx. 2 lbs | Approx. 2.11 lbs | Approx. 2.70 lbs | Approx. 3.19 lbs |
X-dock® Master Controller dimensions | Approx. 4.7 x 5.11 x 9.84 in | |||||
Pac®/X-am® 125 module dimensions | Approx. 3.54 x 5.71 x 9.84 in (90 x 145 x 250 mm) | |||||
X-am® 3500/8000 module dimensions | Approx. 4.80 x 5.71 x 9.84 in (122 x 145 x 250 mm) | |||||
Protection class IP20 | Yes | |||||
Power pack/ power supply | ViVia 24 V (8321849 & 8321850) power pack or car adapter | |||||
Approvals | CE marking | |||||
Ambient conditions | 0 °C to 40 °C | |||||
Gas connections | Draeger X-dock® 5300/6300: 3 test gas inlets for connecting 3 different test gases + one fresh air inlet + one waste gas outlet Draeger X-dock® 6600: 6 test gas inlets for connecting 6 different test gases + one fresh air inlet + one waste gas outlet |
|||||
Connections | USB 2.0: 3 USB 2.0 devices/1 USB host Network connection: Yes: Ethernet Internal Memory Size: 2GB |