- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Casella Sound Meter Single Pack Kit with Standard Items
Item #:
CEL-360XS-K1
Brand:
Casella
Share this product:
CEL-360XS-K1 Sound Meter Single Pack Kit with Standard Items by Casella
The CEL-360S is a fully functional data logging sound level meter that doubles as a personal noise dosimeter. It can be used in a wide variety of applications that require the time history variation of the noise levels to be investigated. Up to 10 different noise parameters can be stored for every interval with a resolution of 1 second to 1 hour. Results can be downloaded to the included software program to view the temporal changes and allow for a full understanding of the noise climate.
Key Benefits
- Data logging of time history changes
- Up to 24 hours capture at 1 second resolution
- Over 220,000 points stored
- Lightweight and easy to use
- Convertible to logging noise dosimeter with different microphone assembly
- Dual mode operation allows simple point and shoot or data storage measurements
- Long battery life
- All the key noise parameters measured and saved
- Download of recordings to pc
Applications
The CEL-360S can be used for many types of noise surveys that require a comprehensive understanding of the time history of the source. These can include workplace noise investigations, site boundary monitoring studies, vehicle pass-by measurements and even compliance checking against local city community noise ordinances. Understanding how the noise levels vary can quickly aid the user reach the most appropriate conclusions.
Measured Parameters
- Instantaneous sound level, Lp
- Duration of run, hh:mm:ss
- Maximum sound level, Lmx
- Minimum sound level, Lmn
- Equivalent continuous noise level, Leq
- Sound exposure level, LE
- Time average level, Lv
- aPeak sound level, Lpk
Operation and use
The CEL-360S meter is very straightforward to use with a simple navigational keypad and matching icons in the display that prompt even the inexperienced user. Select the simple sound level meter mode shown by the SLM icon in the bottom left of the display and use the up and down arrow buttons to cycle through the various noise parameters to reach the required unit of measurement. All sound level meter settings are saved for instant use next time.The average and max values can be reset using the Stop button in the bottom center of the keypad and the Pause button at the bottom left allows unwanted noise to be excluded from the measurement until the user wishes to continue. Any noise occurring during the “pause” time is automatically removed from the ongoing result ensuring the integrity of the overall measurements taken using the CEL-360S instrument.
International standards | Parameters measured and stored | ||
Acoustic accuracy | ANSI S1.4-1983 Type (S)2 ANSI S1.43-1997 IEC 60651:1979 type 2I IEC 60804:1980 type 2 |
Displayed parameters | |
Sound level meter mode |
Lp, Dur, Lmx, Lmn, Leq, LE, Lav, Lpk | ||
Electro-magnetic | EN 50081-1:1992, EN 50081-2:1993, EN 50082-1:1992, EN 50082-2:1995 |
Noise dosimeter/data mode (DATA storing) |
Lp, LAeq, LAE, LeqI, Lav, Lmx, Lmn, 5 x LN%, actual noise dose%, 8 hr projected noise dose%, TWA (at both threshold levels), LEPd, duration of run, current date, time, run #, pause, run in progress, battery voltage, security level |
Measurement ranges (for rms. levels) |
High range 70 – 140 dB Med range 50 – 120 dB Low range 30 – 100 dB |
||
Peak ranges | Top 40 db of each range | ||
Measurements stored | |||
Separate runs | Maximum 50 | Data per profile interval | Up to maximum of 10 |
Max time history size | > 220,000 data points | Physical characteristics | |
Factory setups for data storage modes | 7 - OSHA, MSHA, DoD, ACGIH, ISO85, ISO90, METER | Battery pack | 1 9V radio battery Duracell MN 1604 |
Battery life | 50 hours (approx.) | ||
User setups | 13 – programmed from pc | Size | 4.8 x 2.6 x 1.2 in, 120 x 65 x 30 mm |
Delayed start/stops | Up to max 16 pairs | ||
Threshold levels (dB) | 2 (from 70 to 90 dB) | Weight | 11 oz, 300 gm |
Criterion level (dB) | 1 (from 80 to 90 dB) | Microphone assembly | Electret ¼ in stalk 3.1 in |
Frequency weightings | A, C for rms. C, Lin for peak |
Optional convertible noise dosimeter microphone assembly | Rugged Electret ¼ in microphone on 32 in cable with locking plug, field replaceable item |
Time weightings | Slow, Fast, Impulse, peak | ||
Exchange rates | 3, 4, 5, 6 dB doubling |