- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Apera TN420 Portable White Light Turbidity Meter, Compliant with EPA 180.1 - AI482
Item #:
AI482
Brand:
Apera Instruments
Share this product:
AI482 TN420 Portable White Light Turbidity Meter, Compliant with EPA 180.1 by Apera
Apera TN420 is built with a tungsten filament lamp as the light source and uses the 90° scattering method, which is compliant with the U.S EPA 180.1 method for the determination of turbidity in drinking, ground, surface, and saline waters, domestic and industrial wastes. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operating system and simple calibration.
- Premium-quality tungsten filament lamp as the light source, especially ideal for testing low-range water (<10 NTU). The lamp is replaceable.
- The kit comes with AMCO high-molecular polymer turbidity standard solutions (0, 20, 100, 400, 800 NTU), which are EPA approved primary standards that are safe, non-toxic and disposable, and have a guaranteed one-year shelf life. It is NIST traceable to particle size/distribution and optical density, and its inherent stability means it does not settle from suspension. Store the standards at room temperature. They must not be frozen.
- The average measurement mode automatically takes multiple consecutive readings and calculates their average value.
- Large TFT color screen with simple operation guide, supporting English, Spanish, and Chinese.
- 3.7V rechargeable lithium battery can supply power for up to 20 hours of continuous measurement. The battery life is 5 times longer compared with other products in the market.
- Everything comes in a rugged carrying case, including AMCO calibration solutions (0, 20, 100, 400, 800 NTU), 6 pieces of sample vials, silicone oil, a microfiber wipe, and a user manual.
Measurement Method | 90° scattering measurement, U.S EPA180.1 compliant |
Light Source | Tungsten filament lamp |
Measuring Range | 0 to 1000 NTU (FNU), automatic range switch 0.01 to 19.99 NTU(FNU) 20.0 to 99.9 NTU(FNU) 100 to 1000 NTU(FNU) |
Accuracy | ≤ ±2% of reading+ stray light |
Repeatability | ≤ ± 1% of reading or 0.02 NTU(FNU) (the greater of the two) |
Resolution | 0.01/0.1/1 NTU (FNU) |
Stray Light | ≤0.02 NTU (FNU) |
Calibration Standard | AMCO Polymer or Formazin Solution: 0, 20, 100, 400 and 800NTU (FNU) |
Detector | Silicon photovoltaic |
Measuring Mode | Normal measurement and average measurement |
Display | TFT color screen |
Sample Vial | Φ25x60 mm, high borosilicate glass with lid |
Sample Vial Volume | 18 ml |
Power supply | 3.7V Rechargeable lithium battery |
Working Condition | Temperature: 0 to 50°C (32°F to 122°F) Relative humidity: 0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation |
Instrument sealing grade | IP67 |
Certificates | ISO9001:2015 and CE |
Limited Warranty | 2 years |
Dimension and Weight | Meter: (90×203×80) mm/385g Test Kit: (310×295×110) mm/1.5kg |