- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RKI Instruments FP-40 (3 Minute Averages) Formaldehyde Gas Detector - 73-1061RK
Item #:
73-1061RK
Brand:
RKI Instruments
Share this product:
73-1061RK FP-40 (3 Minute Averages) Formaldehyde Gas Detector by RKI Instruments
These highly sensitive portable gas detectors use photoelectric photometry method with colorimetric detection tab. The sample drawing rate is controlled by a microprocessor. Both the FP-30 and FP-40 have a direct readout of measurement value on an LCD display. The Model FP-30 can detect the new World Health Organization level of 0.08 ppm average for 30 minutes.
Features
- Simple operation
- Specific to Formaldehyde
- Built-in sample draw pump
- Easy to read LCD display
- Self-diagnosis
- Uses photoelectric photometry technology
- Direct digital readout
- Colorimetric detection tablet method
- No false readings from interfering gases
- Operates on 4 AA alkalines
- Stores 99 readings
- No warm up time
Applications
- Furniture and woodworking
- Coating and varnishing
- Engineered wood products
- Medical / veterinary
- Painting & corrosion resistant finishes
- Carpet manufacture & storage
- Adhesives
- Heat treatment operations
- RV/Trailer/mobil home inspecting
*Please note we can only ship RKI products to customers within the United States
Model | FP-30 | FP-40 | |
Detection gas | Formaldeyde (HCHO) in air | ||
Detection range | 0-0.4 ppm (0.005ppm/digit) |
0-1.0 ppm (0.01 ppm/digit) |
0-0.6 ppm |
Detection time | 30 minutes (1,800 sec.) | 15 minutes (900 sec.) | 3 minutes (180 sec.) |
Detection principle | Photoelectric photometry method | ||
Detection method | Colorimetric tablet method (accumulating measurement) | ||
Accuracy | +/- 10% | ||
Display | Digital LCD | ||
Sampling method | Sample drawing with built-in pump | ||
Operating conditions | -10 ~ 40ºC (14 ~ 104ºF), below 90%RH |
5 ~ 35ºC (41 ~ 95ºF), below 90%RH | |
Memory | Detection point: Up to 99 points (automatic recording at the completion of measurement) | ||
Self-diagnosis | Failure of light source and light receiver, low battery voltage, pump failure, system trouble | ||
Power Source | AA size Alkaline batteries (quantity 4) | ||
Continuous Operation | Approximately 12 hours (with no alarm or backlight, with alkaline batteries at 20°C) | ||
Dimension | Approx 85(W) x 190(H) x 40(D)mm, 3.35(W) x 7.48(H) x 1.57(W), | ||
Weight | 500g, 17.6 oz | ||
Standard Accessories | • Detection TAB (20 pcs/pack) ** • Carrying case • AA size alkaline batteries • Operating manual |
||
Warranty | One year material and workmanship |
Test Gas | Concentration | Reading |
Toluene | 1.0 vol.% | 0 ppm |
Benzene | 1.0 vol.% | 0 ppm |
Acetoaldehyde | 100 ppm | 0 ppm |
Carbon monoxide | 50 ppm | 0 ppm |
Carbon dioxide | 1.0 vol.% | 0 ppm |
Ammonia | 25 ppm | 0 ppm |
Acetone | 1.0 vol.% | 0 ppm |
Measurement Place | FP-30 | DNPH method* |
Interior | 0.020 ppm | 0.025 ppm |
Locker | 0.030 ppm | 0.03 ppm |
Furniture | 0.040 ppm | 0.05 ppm |